1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
|
-- Internode-definitions.asn
--
-- Taken from 3GPP TS 25.331 V7.4.0 (2007-03)
-- http://www.3gpp.org/ftp/Specs/archive/25_series/25.331/25331-740.zip/25331-740.doc
--
-- 11.5 RRC information between network nodes
--
Internode-definitions DEFINITIONS AUTOMATIC TAGS ::=
BEGIN
IMPORTS
HandoverToUTRANCommand,
MeasurementReport,
PhysicalChannelReconfiguration,
RadioBearerReconfiguration,
RadioBearerRelease,
RadioBearerSetup,
RRCConnectionSetupComplete-r3-add-ext-IEs,
RRC-FailureInfo,
TransportChannelReconfiguration,
UECapabilityInformation-r3-add-ext-IEs
FROM PDU-definitions
-- Core Network IEs :
CN-DomainIdentity,
CN-DomainInformationList,
CN-DomainInformationListFull,
CN-DRX-CycleLengthCoefficient,
NAS-SystemInformationGSM-MAP,
-- UTRAN Mobility IEs :
CellIdentity,
URA-Identity,
-- User Equipment IEs :
AccessStratumReleaseIndicator,
C-RNTI,
ChipRateCapability,
DL-CapabilityWithSimultaneousHS-DSCHConfig,
DL-PhysChCapabilityFDD-v380ext,
DL-PhysChCapabilityTDD,
DL-PhysChCapabilityTDD-LCR-r4,
GSM-Measurements,
HSDSCH-physical-layer-category,
FailureCauseWithProtErr,
MaxHcContextSpace,
MaximumAM-EntityNumberRLC-Cap,
MaximumRLC-WindowSize,
MaxNoPhysChBitsReceived,
MaxNoDPDCH-BitsTransmitted,
MaxPhysChPerFrame,
MaxPhysChPerSubFrame-r4,
MaxPhysChPerTS,
MaxROHC-ContextSessions-r4,
MaxTS-PerFrame,
MaxTS-PerSubFrame-r4,
MinimumSF-DL,
MultiModeCapability,
MultiRAT-Capability,
NetworkAssistedGPS-Supported,
PhysicalChannelCapability-edch-r6,
PhysicalChannelCapability-r7,
RadioFrequencyBandTDDList,
RF-Capability-r7,
RLC-Capability,
RRC-MessageSequenceNumber,
SecurityCapability,
SimultaneousSCCPCH-DPCH-Reception,
STARTList,
STARTSingle,
START-Value,
SupportOfDedicatedPilotsForChEstimation,
TransportChannelCapability,
TxRxFrequencySeparation,
U-RNTI,
UE-CapabilityContainer-IEs,
UE-MultiModeRAT-Capability,
UE-PowerClassExt,
UE-RadioAccessCapabBandFDDList,
UE-RadioAccessCapabBandFDDList2,
UE-RadioAccessCapabBandFDDList-ext,
UE-RadioAccessCapability,
UE-RadioAccessCapability-v370ext,
UE-RadioAccessCapability-v380ext,
UE-RadioAccessCapability-v3a0ext,
UE-RadioAccessCapability-v3g0ext,
UE-RadioAccessCapability-v4b0ext,
UE-RadioAccessCapability-v590ext,
UE-RadioAccessCapability-v5c0ext,
UE-RadioAccessCapability-v7xyext,
UL-PhysChCapabilityFDD,
UL-PhysChCapabilityFDD-r6,
UL-PhysChCapabilityTDD,
UL-PhysChCapabilityTDD-LCR-r4,
-- Radio Bearer IEs :
PredefinedConfigStatusList,
PredefinedConfigValueTag,
RAB-InformationSetupList,
RAB-InformationSetupList-r4,
RAB-InformationSetupList-r5,
RAB-InformationSetupList-r6-ext,
RAB-InformationSetupList-r6,
RAB-InformationSetupList-v6b0ext,
RAB-InformationSetupList-r7,
RB-Identity,
SRB-InformationSetupList,
SRB-InformationSetupList-r5,
SRB-InformationSetupList-r6,
-- Transport Channel IEs :
CPCH-SetID,
DL-CommonTransChInfo,
DL-CommonTransChInfo-r4,
DL-AddReconfTransChInfoList,
DL-AddReconfTransChInfoList-r4,
DL-AddReconfTransChInfoList-r5,
DRAC-StaticInformationList,
UL-CommonTransChInfo,
UL-CommonTransChInfo-r4,
UL-AddReconfTransChInfoList,
UL-AddReconfTransChInfoList-r6,
UL-AddReconfTransChInfoList-r7,
-- Physical Channel IEs :
PrimaryCPICH-Info,
TPC-CombinationIndex,
ScramblingCodeChange,
TGCFN,
TGPSI,
TGPS-ConfigurationParams,
-- Measurement IEs :
Event1j-r6,
Hysteresis,
Inter-FreqEventCriteriaList-v590ext,
Intra-FreqEventCriteriaList-v590ext,
IntraFreqEvent-1d-r5,
IntraFreqReportingCriteria-1b-r5,
InterRATCellInfoIndication,
MeasuredResultsOnRACHinterFreq,
MeasurementIdentity,
MeasurementReportingMode,
MeasurementType,
MeasurementType-r4,
MeasurementType-r6,
AdditionalMeasurementID-List,
PositionEstimate,
ReportingCellStatus,
ThresholdSFN-GPS-TOW-us,
TimeToTrigger,
-- MBMS IEs :
MBMS-JoinedInformation-r6,
MBMS-SelectedServiceInfo,
-- Other IEs :
GERANIu-RadioAccessCapability,
GSM-MS-RadioAccessCapability,
InterRAT-UE-RadioAccessCapabilityList,
InterRAT-UE-RadioAccessCapability-v590ext,
InterRAT-UE-RadioAccessCapability-v690ext,
UESpecificBehaviourInformation1idle,
UESpecificBehaviourInformation1interRAT
FROM InformationElements
maxCNdomains,
maxNoOfMeas,
maxRB,
maxRBallRABs,
maxRFC3095-CID,
maxSRBsetup,
maxRL,
maxTGPS
FROM Constant-definitions
;
-- Part 1: Class definitions similar to what has been defined in 11.1 for RRC messages
-- Information that is tranferred in the same direction and across the same path is grouped
-- ***************************************************
--
-- RRC information, to target RNC
--
-- ***************************************************
-- RRC Information to target RNC sent either from source RNC or from another RAT
ToTargetRNC-Container ::= CHOICE {
interRATHandoverInfo InterRATHandoverInfoWithInterRATCapabilities-r3,
srncRelocation SRNC-RelocationInfo-r3,
rfc3095-ContextInfo RFC3095-ContextInfo-r5,
extension NULL
}
-- ***************************************************
--
-- RRC information, target RNC to source RNC
--
-- ***************************************************
TargetRNC-ToSourceRNC-Container ::= CHOICE {
radioBearerSetup RadioBearerSetup,
radioBearerReconfiguration RadioBearerReconfiguration,
radioBearerRelease RadioBearerRelease,
transportChannelReconfiguration TransportChannelReconfiguration,
physicalChannelReconfiguration PhysicalChannelReconfiguration,
rrc-FailureInfo RRC-FailureInfo,
-- IE dl-DCCHmessage consists of an octet string that includes the IE DL-DCCH-Message
dL-DCCHmessage OCTET STRING,
extension NULL
}
-- Part 2: Container definitions, similar to the PDU definitions in 11.2 for RRC messages
-- In alphabetical order
-- ***************************************************
--
-- Handover to UTRAN information
--
-- ***************************************************
InterRATHandoverInfoWithInterRATCapabilities-r3 ::= CHOICE {
r3 SEQUENCE {
-- IE InterRATHandoverInfoWithInterRATCapabilities-r3-IEs also
-- includes non critical extensions
interRATHandoverInfo-r3 InterRATHandoverInfoWithInterRATCapabilities-r3-IEs,
v390NonCriticalExtensions SEQUENCE {
interRATHandoverInfoWithInterRATCapabilities-v390ext
InterRATHandoverInfoWithInterRATCapabilities-v390ext-IEs,
-- Reserved for future non critical extension
v690NonCriticalExtensions SEQUENCE {
interRATHandoverInfoWithInterRATCapabilities-v690ext
InterRATHandoverInfoWithInterRATCapabilities-v690ext-IEs,
nonCriticalExtensions SEQUENCE {} OPTIONAL
} OPTIONAL
} OPTIONAL
},
criticalExtensions SEQUENCE {}
}
InterRATHandoverInfoWithInterRATCapabilities-r3-IEs ::= SEQUENCE {
-- The order of the IEs may not reflect the tabular format
-- but has been chosen to simplify the handling of the information in the BSC
-- Other IEs
ue-RATSpecificCapability InterRAT-UE-RadioAccessCapabilityList OPTIONAL,
-- interRATHandoverInfo, Octet string is used to obtain 8 bit length field prior to
-- actual information. This makes it possible for BSS to transparently handle information
-- received via GSM air interface even when it includes non critical extensions.
-- The octet string shall include the InterRATHandoverInfo information
-- The BSS can re-use the 44.018 length field received from the MS
interRATHandoverInfo OCTET STRING (SIZE (0..255))
}
InterRATHandoverInfoWithInterRATCapabilities-v390ext-IEs ::= SEQUENCE {
-- User equipment IEs
failureCauseWithProtErr FailureCauseWithProtErr OPTIONAL
}
InterRATHandoverInfoWithInterRATCapabilities-v690ext-IEs ::= SEQUENCE {
-- Other IEs
ue-RATSpecificCapability-v690ext InterRAT-UE-RadioAccessCapability-v690ext OPTIONAL
}
-- ***************************************************
--
-- RFC3095 context, source RNC to target RNC
--
-- ***************************************************
RFC3095-ContextInfo-r5 ::= CHOICE {
r5 SEQUENCE {
rFC3095-ContextInfoList-r5 RFC3095-ContextInfoList-r5,
-- Reserved for future non critical extension
nonCriticalExtensions SEQUENCE {} OPTIONAL
},
criticalExtensions SEQUENCE {}
}
RFC3095-ContextInfoList-r5 ::= SEQUENCE (SIZE (1..maxRBallRABs)) OF
RFC3095-ContextInfo
-- ***************************************************
--
-- SRNC Relocation information
--
-- ***************************************************
SRNC-RelocationInfo-r3 ::= CHOICE {
r3 SEQUENCE {
sRNC-RelocationInfo-r3 SRNC-RelocationInfo-r3-IEs,
v380NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v380ext SRNC-RelocationInfo-v380ext-IEs,
-- Reserved for future non critical extension
v390NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v390ext SRNC-RelocationInfo-v390ext-IEs,
v3a0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v3a0ext SRNC-RelocationInfo-v3a0ext-IEs,
v3b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v3b0ext SRNC-RelocationInfo-v3b0ext-IEs,
v3c0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v3c0ext SRNC-RelocationInfo-v3c0ext-IEs,
laterNonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v3d0ext SRNC-RelocationInfo-v3d0ext-IEs,
-- Container for additional R99 extensions
sRNC-RelocationInfo-r3-add-ext BIT STRING
(CONTAINING SRNC-RelocationInfo-v3h0ext-IEs) OPTIONAL,
v3g0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v3g0ext SRNC-RelocationInfo-v3g0ext-IEs,
v4b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v4b0ext SRNC-RelocationInfo-v4b0ext-IEs,
v590NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v590ext
SRNC-RelocationInfo-v590ext-IEs,
v5a0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5a0ext
SRNC-RelocationInfo-v5a0ext-IEs,
v5b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5b0ext
SRNC-RelocationInfo-v5b0ext-IEs,
v5c0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5c0ext
SRNC-RelocationInfo-v5c0ext-IEs,
v690NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v690ext
SRNC-RelocationInfo-v690ext-IEs,
v6b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v6b0ext
SRNC-RelocationInfo-v6b0ext-IEs,
v7xyNonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v7xyext
SRNC-RelocationInfo-v7xyext-IEs,
-- Reserved for future non critical
-- extension
nonCriticalExtensions
SEQUENCE {} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
},
later-than-r3 CHOICE {
r4 SEQUENCE {
sRNC-RelocationInfo-r4 SRNC-RelocationInfo-r4-IEs,
v4d0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v4d0ext SRNC-RelocationInfo-v4d0ext-IEs,
-- Container for adding non critical extensions after freezing REL-5
sRNC-RelocationInfo-r4-add-ext BIT STRING OPTIONAL,
v590NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v590ext SRNC-RelocationInfo-v590ext-IEs,
v5a0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5a0ext SRNC-RelocationInfo-v5a0ext-IEs,
v5b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5b0ext SRNC-RelocationInfo-v5b0ext-IEs,
v5c0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5c0ext SRNC-RelocationInfo-v5c0ext-IEs,
v690NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v690ext SRNC-RelocationInfo-v690ext-IEs,
v6b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v6b0ext
SRNC-RelocationInfo-v6b0ext-IEs,
v7xyNonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v7xyext
SRNC-RelocationInfo-v7xyext-IEs,
nonCriticalExtensions SEQUENCE {} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
},
criticalExtensions CHOICE {
r5 SEQUENCE {
sRNC-RelocationInfo-r5 SRNC-RelocationInfo-r5-IEs,
sRNC-RelocationInfo-r5-add-ext BIT STRING OPTIONAL,
v5a0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5a0ext SRNC-RelocationInfo-v5a0ext-IEs,
v5b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5b0ext SRNC-RelocationInfo-v5b0ext-IEs,
v5c0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v5c0ext SRNC-RelocationInfo-v5c0ext-IEs,
v690NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v690ext SRNC-RelocationInfo-v690ext-IEs,
v6b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v6b0ext SRNC-RelocationInfo-v6b0ext-IEs,
v7xyNonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v7xyext
SRNC-RelocationInfo-v7xyext-IEs,
nonCriticalExtensions SEQUENCE {} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
} OPTIONAL
},
criticalExtensions CHOICE {
r6 SEQUENCE {
sRNC-RelocationInfo-r6 SRNC-RelocationInfo-r6-IEs,
sRNC-RelocationInfo-r6-add-ext BIT STRING OPTIONAL,
v6b0NonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v6b0ext SRNC-RelocationInfo-v6b0ext-IEs,
v7xyNonCriticalExtensions SEQUENCE {
sRNC-RelocationInfo-v7xyext SRNC-RelocationInfo-v7xyext-IEs,
nonCriticalExtensions SEQUENCE {} OPTIONAL
} OPTIONAL
} OPTIONAL
},
criticalExtensions CHOICE {
r7 SEQUENCE {
sRNC-RelocationInfo-r7 SRNC-RelocationInfo-r7-IEs,
sRNC-RelocationInfo-r7-add-ext BIT STRING OPTIONAL,
nonCriticalExtensions SEQUENCE {} OPTIONAL
},
criticalExtensions SEQUENCE {}
}
}
}
}
}
SRNC-RelocationInfo-r3-IEs ::= SEQUENCE {
-- Non-RRC IEs
stateOfRRC StateOfRRC,
stateOfRRC-Procedure StateOfRRC-Procedure,
-- Ciphering related information IEs
-- If the extension v380 is included use the extension for the ciphering status per CN domain
cipheringStatus CipheringStatus,
-- If ciphering status is started and the IE latestConfiguredCN-Domain should be included,
-- the IE cn-DomainIdentity (in SRNC-RelocationInfo-v380ext-IEs) shall be used instead.
calculationTimeForCiphering CalculationTimeForCiphering OPTIONAL,
-- The order of occurrence in the IE cipheringInfoPerRB-List is the
-- same as the RBs in SRB-InformationSetupList in RAB-InformationSetupList.
-- The signalling RBs are supposed to be listed
-- first. Only UM and AM RBs that are ciphered are listed here
cipheringInfoPerRB-List CipheringInfoPerRB-List OPTIONAL,
count-C-List COUNT-C-List OPTIONAL,
integrityProtectionStatus IntegrityProtectionStatus,
-- In the IE srb-SpecificIntegrityProtInfo, the first information listed corresponds to
-- signalling radio bearer RB0 and after the order of occurrence is the same as the SRBs in
-- SRB-InformationSetupList
-- The target RNC may ignore the IE srb-SpecificIntegrityProtInfo if the
-- IE integrityProtectionStatus has the value "not started".
srb-SpecificIntegrityProtInfo SRB-SpecificIntegrityProtInfoList,
implementationSpecificParams ImplementationSpecificParams OPTIONAL,
-- User equipment IEs
u-RNTI U-RNTI,
c-RNTI C-RNTI OPTIONAL,
ue-RadioAccessCapability UE-RadioAccessCapability,
ue-Positioning-LastKnownPos UE-Positioning-LastKnownPos OPTIONAL,
-- Other IEs
ue-RATSpecificCapability InterRAT-UE-RadioAccessCapabilityList OPTIONAL,
-- UTRAN mobility IEs
ura-Identity URA-Identity OPTIONAL,
-- Core network IEs
cn-CommonGSM-MAP-NAS-SysInfo NAS-SystemInformationGSM-MAP,
cn-DomainInformationList CN-DomainInformationList OPTIONAL,
-- Measurement IEs
ongoingMeasRepList OngoingMeasRepList OPTIONAL,
-- Radio bearer IEs
predefinedConfigStatusList PredefinedConfigStatusList,
srb-InformationList SRB-InformationSetupList,
rab-InformationList RAB-InformationSetupList OPTIONAL,
-- Transport channel IEs
ul-CommonTransChInfo UL-CommonTransChInfo OPTIONAL,
ul-TransChInfoList UL-AddReconfTransChInfoList OPTIONAL,
modeSpecificInfo CHOICE {
fdd SEQUENCE {
-- dummy and dummy2 are not used in this version of the specification, they should
-- not be sent and if received they should be ignored.
dummy CPCH-SetID OPTIONAL,
dummy2 DRAC-StaticInformationList OPTIONAL
},
tdd NULL
},
dl-CommonTransChInfo DL-CommonTransChInfo OPTIONAL,
dl-TransChInfoList DL-AddReconfTransChInfoList OPTIONAL,
-- Measurement report
measurementReport MeasurementReport OPTIONAL
}
SRNC-RelocationInfo-v380ext-IEs ::= SEQUENCE {
-- Ciphering related information IEs
-- In the SRNC-RelocationInfo-r3-IEs, the IE 'cn-DomainIdentity' is used to represent the
-- IE 'Latest configured CN domain' in the tabular.
cn-DomainIdentity CN-DomainIdentity,
cipheringStatusList CipheringStatusList
}
SRNC-RelocationInfo-v390ext-IEs ::= SEQUENCE {
cn-DomainInformationList-v390ext CN-DomainInformationList-v390ext OPTIONAL,
ue-RadioAccessCapability-v370ext UE-RadioAccessCapability-v370ext OPTIONAL,
ue-RadioAccessCapability-v380ext UE-RadioAccessCapability-v380ext OPTIONAL,
dl-PhysChCapabilityFDD-v380ext DL-PhysChCapabilityFDD-v380ext,
failureCauseWithProtErr FailureCauseWithProtErr OPTIONAL
}
SRNC-RelocationInfo-v3a0ext-IEs ::= SEQUENCE {
cipheringInfoForSRB1-v3a0ext CipheringInfoPerRB-List-v3a0ext,
ue-RadioAccessCapability-v3a0ext UE-RadioAccessCapability-v3a0ext OPTIONAL,
-- cn-domain identity for IE startValueForCiphering-v3a0ext is specified
-- in subsequent extension (SRNC-RelocationInfo-v3b0ext-IEs)
startValueForCiphering-v3a0ext START-Value
}
SRNC-RelocationInfo-v3b0ext-IEs ::= SEQUENCE {
-- cn-domain identity for IE startValueForCiphering-v3a0ext included in previous extension
cn-DomainIdentity CN-DomainIdentity,
-- the IE startValueForCiphering-v3b0ext contains the start values for each CN Domain. The
-- value of start indicated by the IE startValueForCiphering-v3a0ext should be set to the
-- same value as the start-Value for the corresponding cn-DomainIdentity in the IE
-- startValueForCiphering-v3b0ext
startValueForCiphering-v3b0ext STARTList2 OPTIONAL
}
SRNC-RelocationInfo-v3c0ext-IEs ::= SEQUENCE {
-- IE rb-IdentityForHOMessage includes the identity of the RB used by the source SRNC
-- to send the message contained in the IE "TargetRNC-ToSourceRNC-Container".
-- Only included if type is "UE involved"
rb-IdentityForHOMessage RB-Identity OPTIONAL
}
SRNC-RelocationInfo-v3d0ext-IEs ::= SEQUENCE {
-- User equipment IEs
uESpecificBehaviourInformation1idle UESpecificBehaviourInformation1idle OPTIONAL,
uESpecificBehaviourInformation1interRAT UESpecificBehaviourInformation1interRAT OPTIONAL
}
SRNC-RelocationInfo-v3g0ext-IEs ::= SEQUENCE {
ue-RadioAccessCapability-v3g0ext UE-RadioAccessCapability-v3g0ext OPTIONAL
}
SRNC-RelocationInfo-v3h0ext-IEs ::= SEQUENCE {
tpc-CombinationInfoList TPC-CombinationInfoList OPTIONAL,
nonCriticalExtension SEQUENCE {} OPTIONAL
}
SRNC-RelocationInfo-v4d0ext-IEs ::= SEQUENCE {
tpc-CombinationInfoList TPC-CombinationInfoList OPTIONAL
}
TPC-CombinationInfoList ::= SEQUENCE (SIZE (1..maxRL)) OF
TPC-Combination-Info
STARTList2 ::= SEQUENCE (SIZE (2..maxCNdomains)) OF
STARTSingle
SRNC-RelocationInfo-v4b0ext-IEs ::= SEQUENCE {
ue-RadioAccessCapability-v4b0ext UE-RadioAccessCapability-v4b0ext OPTIONAL
}
SRNC-RelocationInfo-v590ext-IEs ::= SEQUENCE {
ue-RadioAccessCapability-v590ext UE-RadioAccessCapability-v590ext OPTIONAL,
ue-RATSpecificCapability-v590ext InterRAT-UE-RadioAccessCapability-v590ext OPTIONAL
}
SRNC-RelocationInfo-v5a0ext-IEs ::= SEQUENCE {
storedCompressedModeInfo StoredCompressedModeInfo OPTIONAL
}
SRNC-RelocationInfo-v5b0ext-IEs ::= SEQUENCE {
interRATCellInfoIndication InterRATCellInfoIndication OPTIONAL
}
SRNC-RelocationInfo-v5c0ext-IEs ::= SEQUENCE {
ue-RadioAccessCapability-v5c0ext UE-RadioAccessCapability-v5c0ext OPTIONAL
}
CipheringInfoPerRB-List-v3a0ext ::= SEQUENCE {
dl-UM-SN BIT STRING (SIZE (7))
}
CipheringStatusList ::= SEQUENCE (SIZE (1..maxCNdomains)) OF
CipheringStatusCNdomain
CipheringStatusCNdomain ::= SEQUENCE {
cn-DomainIdentity CN-DomainIdentity,
cipheringStatus CipheringStatus
}
CodeChangeStatusList ::= SEQUENCE (SIZE (1..maxRL)) OF
CodeChangeStatus
CodeChangeStatus ::= SEQUENCE {
primaryCPICH-Info PrimaryCPICH-Info,
scramblingCodeChange ScramblingCodeChange
}
StoredCompressedModeInfo ::= SEQUENCE {
storedTGP-SequenceList StoredTGP-SequenceList,
codeChangeStatusList CodeChangeStatusList OPTIONAL
}
StoredTGP-SequenceList ::= SEQUENCE (SIZE (1..maxTGPS)) OF
StoredTGP-Sequence
StoredTGP-Sequence ::= SEQUENCE {
tgpsi TGPSI,
current-tgps-Status CHOICE {
active SEQUENCE {
tgcfn TGCFN
},
inactive NULL
},
tgps-ConfigurationParams TGPS-ConfigurationParams OPTIONAL
}
SRNC-RelocationInfo-r4-IEs ::= SEQUENCE {
-- Non-RRC IEs
-- IE rb-IdentityForHOMessage includes the identity of the RB used by the source SRNC
-- to send the message contained in the IE "TargetRNC-ToSourceRNC-Container".
-- Only included if type is "UE involved"
rb-IdentityForHOMessage RB-Identity OPTIONAL,
stateOfRRC StateOfRRC,
stateOfRRC-Procedure StateOfRRC-Procedure,
-- Ciphering related information IEs
cipheringStatusList CipheringStatusList-r4,
latestConfiguredCN-Domain CN-DomainIdentity,
calculationTimeForCiphering CalculationTimeForCiphering OPTIONAL,
count-C-List COUNT-C-List OPTIONAL,
cipheringInfoPerRB-List CipheringInfoPerRB-List-r4 OPTIONAL,
-- Integrity protection related information IEs
integrityProtectionStatus IntegrityProtectionStatus,
-- The target RNC may ignore the IE srb-SpecificIntegrityProtInfo if the
-- IE integrityProtectionStatus has the value "not started".
srb-SpecificIntegrityProtInfo SRB-SpecificIntegrityProtInfoList,
implementationSpecificParams ImplementationSpecificParams OPTIONAL,
-- User equipment IEs
u-RNTI U-RNTI,
c-RNTI C-RNTI OPTIONAL,
ue-RadioAccessCapability UE-RadioAccessCapability-r4,
ue-RadioAccessCapability-ext UE-RadioAccessCapabBandFDDList OPTIONAL,
ue-Positioning-LastKnownPos UE-Positioning-LastKnownPos OPTIONAL,
uESpecificBehaviourInformation1idle UESpecificBehaviourInformation1idle OPTIONAL,
uESpecificBehaviourInformation1interRAT UESpecificBehaviourInformation1interRAT OPTIONAL,
-- Other IEs
ue-RATSpecificCapability InterRAT-UE-RadioAccessCapabilityList OPTIONAL,
-- UTRAN mobility IEs
ura-Identity URA-Identity OPTIONAL,
-- Core network IEs
cn-CommonGSM-MAP-NAS-SysInfo NAS-SystemInformationGSM-MAP,
cn-DomainInformationList CN-DomainInformationListFull OPTIONAL,
-- Measurement IEs
ongoingMeasRepList OngoingMeasRepList-r4 OPTIONAL,
-- Radio bearer IEs
predefinedConfigStatusList PredefinedConfigStatusList,
srb-InformationList SRB-InformationSetupList,
rab-InformationList RAB-InformationSetupList-r4 OPTIONAL,
-- Transport channel IEs
ul-CommonTransChInfo UL-CommonTransChInfo-r4 OPTIONAL,
ul-TransChInfoList UL-AddReconfTransChInfoList OPTIONAL,
-- 'dummy', 'dummy1' and 'dummy2' are not used in this version of the specification,
-- they should not be sent and if received they should be ignored.
dummy CHOICE {
fdd SEQUENCE {
dummy1 CPCH-SetID OPTIONAL,
dummy2 DRAC-StaticInformationList OPTIONAL
},
tdd NULL
} OPTIONAL,
dl-CommonTransChInfo DL-CommonTransChInfo-r4 OPTIONAL,
dl-TransChInfoList DL-AddReconfTransChInfoList-r4 OPTIONAL,
-- Measurement report
measurementReport MeasurementReport OPTIONAL,
failureCause FailureCauseWithProtErr OPTIONAL
}
SRNC-RelocationInfo-r5-IEs ::= SEQUENCE {
-- Non-RRC IEs
-- IE rb-IdentityForHOMessage includes the identity of the RB used by the source SRNC
-- to send the message contained in the IE "TargetRNC-ToSourceRNC-Container".
-- Only included if type is "UE involved"
rb-IdentityForHOMessage RB-Identity OPTIONAL,
stateOfRRC StateOfRRC,
stateOfRRC-Procedure StateOfRRC-Procedure,
-- Ciphering related information IEs
cipheringStatusList CipheringStatusList-r4,
latestConfiguredCN-Domain CN-DomainIdentity,
calculationTimeForCiphering CalculationTimeForCiphering OPTIONAL,
count-C-List COUNT-C-List OPTIONAL,
cipheringInfoPerRB-List CipheringInfoPerRB-List-r4 OPTIONAL,
-- Integrity protection related information IEs
integrityProtectionStatus IntegrityProtectionStatus,
srb-SpecificIntegrityProtInfo SRB-SpecificIntegrityProtInfoList OPTIONAL,
implementationSpecificParams ImplementationSpecificParams OPTIONAL,
-- User equipment IEs
u-RNTI U-RNTI,
c-RNTI C-RNTI OPTIONAL,
ue-RadioAccessCapability UE-RadioAccessCapability-r5,
ue-RadioAccessCapability-ext UE-RadioAccessCapabBandFDDList OPTIONAL,
ue-Positioning-LastKnownPos UE-Positioning-LastKnownPos OPTIONAL,
uESpecificBehaviourInformation1idle
UESpecificBehaviourInformation1idle OPTIONAL,
uESpecificBehaviourInformation1interRAT
UESpecificBehaviourInformation1interRAT OPTIONAL,
-- Other IEs
ue-RATSpecificCapability InterRAT-UE-RadioAccessCapabilityList-r5 OPTIONAL,
-- UTRAN mobility IEs
ura-Identity URA-Identity OPTIONAL,
-- Core network IEs
cn-CommonGSM-MAP-NAS-SysInfo NAS-SystemInformationGSM-MAP,
cn-DomainInformationList CN-DomainInformationListFull OPTIONAL,
-- Measurement IEs
ongoingMeasRepList OngoingMeasRepList-r5 OPTIONAL,
-- Radio bearer IEs
predefinedConfigStatusList PredefinedConfigStatusList,
srb-InformationList SRB-InformationSetupList-r5,
rab-InformationList RAB-InformationSetupList-r5 OPTIONAL,
-- Transport channel IEs
ul-CommonTransChInfo UL-CommonTransChInfo-r4 OPTIONAL,
ul-TransChInfoList UL-AddReconfTransChInfoList OPTIONAL,
-- 'dummy', 'dummy1' and 'dummy2' are not used in this version of the specification,
-- they should not be sent and if received they should be ignored.
dummy CHOICE {
fdd SEQUENCE {
dummy1 CPCH-SetID OPTIONAL,
dummy2 DRAC-StaticInformationList OPTIONAL
},
tdd NULL
} OPTIONAL,
dl-CommonTransChInfo DL-CommonTransChInfo-r4 OPTIONAL,
dl-TransChInfoList DL-AddReconfTransChInfoList-r5 OPTIONAL,
-- PhyCH IEs
tpc-CombinationInfoList TPC-CombinationInfoList OPTIONAL,
-- Measurement report
measurementReport MeasurementReport OPTIONAL,
-- Other IEs
failureCause FailureCauseWithProtErr OPTIONAL
}
SRNC-RelocationInfo-v690ext-IEs ::= SEQUENCE {
-- User equipment IEs
-- IE ueCapabilityContainer is used for the transparent transfer of capability information
-- received from the UE
ueCapabilityContainer BIT STRING
(CONTAINING UE-CapabilityContainer-IEs) OPTIONAL,
-- IE ueCapabilityContainer-RSC and IE ueCapabilityContainer-UCI are used for the
-- transparent transfer of capability information received from the UE that was introduced
-- in a release independent manner, i.e., transferred within a VLEC. These UE capabilities
-- are included both in the RRC CONNECTION SETUP COMPLETE and the UE CAPABILITY INFORMATION
-- messages. Only the VLEC of one message needs to be included i.e. the one from these
-- messages that was last received.
-- Case 1: If the last received message was a RRC CONNECTION SETUP COMPLETE (RSC)
ueCapabilityContainer-RSC BIT STRING
(CONTAINING RRCConnectionSetupComplete-r3-add-ext-IEs) OPTIONAL,
-- Case 2: If the last received message was a UE CAPABILITY INFORMATION (UCI)
ueCapabilityContainer-UCI BIT STRING
(CONTAINING UECapabilityInformation-r3-add-ext-IEs) OPTIONAL,
-- Radio bearer IEs
rab-InformationSetupList RAB-InformationSetupList-r6-ext OPTIONAL,
-- Measurement report
measuredResultsOnRACHinterFreq MeasuredResultsOnRACHinterFreq OPTIONAL,
-- MBMS IEs
mbms-JoinedInformation MBMS-JoinedInformation-r6 OPTIONAL,
-- Measurement IEs
intraFreqReportingCriteria IntraFreqReportingCriteria-r6-ext OPTIONAL
}
SRNC-RelocationInfo-r6-IEs ::= SEQUENCE {
-- Non-RRC IEs
-- IE rb-IdentityForHOMessage includes the identity of the RB used by the source SRNC
-- to send the message contained in the IE "TargetRNC-ToSourceRNC-Container".
-- Only included if type is "UE involved"
rb-IdentityForHOMessage RB-Identity OPTIONAL,
stateOfRRC StateOfRRC,
stateOfRRC-Procedure StateOfRRC-Procedure,
-- Ciphering related information IEs
cipheringStatusList CipheringStatusList-r4,
latestConfiguredCN-Domain CN-DomainIdentity,
calculationTimeForCiphering CalculationTimeForCiphering OPTIONAL,
count-C-List COUNT-C-List OPTIONAL,
cipheringInfoPerRB-List CipheringInfoPerRB-List-r4 OPTIONAL,
-- Integrity protection related information IEs
integrityProtectionStatus IntegrityProtectionStatus,
srb-SpecificIntegrityProtInfo SRB-SpecificIntegrityProtInfoList OPTIONAL,
implementationSpecificParams ImplementationSpecificParams OPTIONAL,
-- User equipment IEs
u-RNTI U-RNTI,
c-RNTI C-RNTI OPTIONAL,
ue-RadioAccessCapability UE-RadioAccessCapability-r6,
ue-RadioAccessCapability-ext UE-RadioAccessCapabBandFDDList OPTIONAL,
ue-Positioning-LastKnownPos UE-Positioning-LastKnownPos OPTIONAL,
uESpecificBehaviourInformation1idle
UESpecificBehaviourInformation1idle OPTIONAL,
uESpecificBehaviourInformation1interRAT
UESpecificBehaviourInformation1interRAT OPTIONAL,
-- IE ueCapabilityContainer is used for the transparent transfer of capability information
-- received from the UE
ueCapabilityContainer BIT STRING
(CONTAINING UE-CapabilityContainer-IEs) OPTIONAL,
-- IE ueCapabilityContainer-RSC and IE ueCapabilityContainer-UCI are used for the
-- transparent transfer of capability information received from the UE that was introduced
-- in a release independent manner, i.e., transferred within a VLEC. These UE capabilities
-- are included both in the RRC CONNECTION SETUP COMPLETE and the UE CAPABILITY INFORMATION
-- messages. Only the VLEC of one message needs to be included i.e. the one from these
-- messages that was last received.
-- Case 1: If the last received message was a RRC CONNECTION SETUP COMPLETE (RSC)
ueCapabilityContainer-RSC BIT STRING
(CONTAINING RRCConnectionSetupComplete-r3-add-ext-IEs) OPTIONAL,
-- Case 2: If the last received message was a UE CAPABILITY INFORMATION (UCI)
ueCapabilityContainer-UCI BIT STRING
(CONTAINING UECapabilityInformation-r3-add-ext-IEs) OPTIONAL,
-- Other IEs
ue-RATSpecificCapability InterRAT-UE-RadioAccessCapabilityList-r5 OPTIONAL,
-- UTRAN mobility IEs
ura-Identity URA-Identity OPTIONAL,
-- Core network IEs
cn-CommonGSM-MAP-NAS-SysInfo NAS-SystemInformationGSM-MAP,
cn-DomainInformationList CN-DomainInformationListFull OPTIONAL,
-- Measurement IEs
ongoingMeasRepList OngoingMeasRepList-r6 OPTIONAL,
interRATCellInfoIndication InterRATCellInfoIndication OPTIONAL,
-- Radio bearer IEs
predefinedConfigStatusList PredefinedConfigStatusList,
srb-InformationList SRB-InformationSetupList-r6,
rab-InformationList RAB-InformationSetupList-r6 OPTIONAL,
-- Transport channel IEs
ul-CommonTransChInfo UL-CommonTransChInfo-r4 OPTIONAL,
ul-TransChInfoList UL-AddReconfTransChInfoList-r6 OPTIONAL,
dl-CommonTransChInfo DL-CommonTransChInfo-r4 OPTIONAL,
dl-TransChInfoList DL-AddReconfTransChInfoList-r5 OPTIONAL,
-- PhyCH IEs
tpc-CombinationInfoList TPC-CombinationInfoList OPTIONAL,
storedCompressedModeInfo StoredCompressedModeInfo OPTIONAL,
-- Measurement report
measurementReport BIT STRING
(CONTAINING MeasurementReport) OPTIONAL,
-- Other IEs
failureCause FailureCauseWithProtErr OPTIONAL,
-- MBMS IEs
mbms-JoinedInformation MBMS-JoinedInformation-r6 OPTIONAL
}
SRNC-RelocationInfo-v6b0ext-IEs ::= SEQUENCE {
-- The order of the RABs in IE rab-InformationSetupListExt is the same as
-- in IE rab-InformationSetupList that is included in this message
rab-InformationSetupListExt RAB-InformationSetupList-v6b0ext OPTIONAL,
mbmsSelectedServiceInfo MBMS-SelectedServiceInfo
}
SRNC-RelocationInfo-r7-IEs ::= SEQUENCE {
-- Non-RRC IEs
-- IE rb-IdentityForHOMessage includes the identity of the RB used by the source SRNC
-- to send the message contained in the IE "TargetRNC-ToSourceRNC-Container".
-- Only included if type is "UE involved"
rb-IdentityForHOMessage RB-Identity OPTIONAL,
stateOfRRC StateOfRRC,
stateOfRRC-Procedure StateOfRRC-Procedure,
-- Ciphering related information IEs
cipheringStatusList CipheringStatusList-r4,
latestConfiguredCN-Domain CN-DomainIdentity,
calculationTimeForCiphering CalculationTimeForCiphering OPTIONAL,
count-C-List COUNT-C-List OPTIONAL,
cipheringInfoPerRB-List CipheringInfoPerRB-List-r4 OPTIONAL,
-- Integrity protection related information IEs
integrityProtectionStatus IntegrityProtectionStatus,
srb-SpecificIntegrityProtInfo SRB-SpecificIntegrityProtInfoList OPTIONAL,
implementationSpecificParams ImplementationSpecificParams OPTIONAL,
-- User equipment IEs
u-RNTI U-RNTI,
c-RNTI C-RNTI OPTIONAL,
ue-RadioAccessCapability UE-RadioAccessCapability-r6,
ue-RadioAccessCapability-ext UE-RadioAccessCapabBandFDDList OPTIONAL,
ue-Positioning-LastKnownPos UE-Positioning-LastKnownPos OPTIONAL,
uESpecificBehaviourInformation1idle
UESpecificBehaviourInformation1idle OPTIONAL,
uESpecificBehaviourInformation1interRAT
UESpecificBehaviourInformation1interRAT OPTIONAL,
-- IE ueCapabilityContainer is used for the transparent transfer of capability information
-- received from the UE
ueCapabilityContainer BIT STRING
(CONTAINING UE-CapabilityContainer-IEs) OPTIONAL,
-- IE ueCapabilityContainer-RSC and IE ueCapabilityContainer-UCI are used for the
-- transparent transfer of capability information received from the UE that was introduced
-- in a release independent manner, i.e., transferred within a VLEC. These UE capabilities
-- are included both in the RRC CONNECTION SETUP COMPLETE and the UE CAPABILITY INFORMATION
-- messages. Only the VLEC of one message needs to be included i.e. the one from these
-- messages that was last received.
-- Case 1: If the last received message was a RRC CONNECTION SETUP COMPLETE (RSC)
ueCapabilityContainer-RSC BIT STRING
(CONTAINING RRCConnectionSetupComplete-r3-add-ext-IEs) OPTIONAL,
-- Case 2: If the last received message was a UE CAPABILITY INFORMATION (UCI)
ueCapabilityContainer-UCI BIT STRING
(CONTAINING UECapabilityInformation-r3-add-ext-IEs) OPTIONAL,
-- Other IEs
ue-RATSpecificCapability InterRAT-UE-RadioAccessCapabilityList-r5 OPTIONAL,
-- UTRAN mobility IEs
ura-Identity URA-Identity OPTIONAL,
-- Core network IEs
cn-CommonGSM-MAP-NAS-SysInfo NAS-SystemInformationGSM-MAP,
cn-DomainInformationList CN-DomainInformationListFull OPTIONAL,
-- Measurement IEs
ongoingMeasRepList OngoingMeasRepList-r7 OPTIONAL,
interRATCellInfoIndication InterRATCellInfoIndication OPTIONAL,
-- Radio bearer IEs
predefinedConfigStatusList PredefinedConfigStatusList,
srb-InformationList SRB-InformationSetupList-r6,
rab-InformationList RAB-InformationSetupList-r6 OPTIONAL,
-- Transport channel IEs
ul-CommonTransChInfo UL-CommonTransChInfo-r4 OPTIONAL,
ul-TransChInfoList UL-AddReconfTransChInfoList-r7 OPTIONAL,
dl-CommonTransChInfo DL-CommonTransChInfo-r4 OPTIONAL,
dl-TransChInfoList DL-AddReconfTransChInfoList-r5 OPTIONAL,
-- PhyCH IEs
tpc-CombinationInfoList TPC-CombinationInfoList OPTIONAL,
storedCompressedModeInfo StoredCompressedModeInfo OPTIONAL,
-- Measurement report
measurementReport MeasurementReport OPTIONAL,
-- Other IEs
failureCause FailureCauseWithProtErr OPTIONAL,
-- MBMS IEs
mbms-JoinedInformation MBMS-JoinedInformation-r6 OPTIONAL
}
SRNC-RelocationInfo-v7xyext-IEs ::= SEQUENCE {
ue-RadioAccessCapability-v7xyext UE-RadioAccessCapability-v7xyext OPTIONAL,
thresholdSFN-GPS-TOW-us ThresholdSFN-GPS-TOW-us OPTIONAL
}
-- IE definitions
CalculationTimeForCiphering ::= SEQUENCE {
cell-Id CellIdentity,
sfn INTEGER (0..4095)
}
CipheringInfoPerRB ::= SEQUENCE {
dl-HFN BIT STRING (SIZE (20..25)),
ul-HFN BIT STRING (SIZE (20..25))
}
CipheringInfoPerRB-r4 ::= SEQUENCE {
rb-Identity RB-Identity,
dl-HFN BIT STRING (SIZE (20..25)),
dl-UM-SN BIT STRING (SIZE (7)) OPTIONAL,
ul-HFN BIT STRING (SIZE (20..25))
}
-- TABULAR: CipheringInfoPerRB-List, multiplicity value numberOfRadioBearers
-- has been replaced with maxRB.
CipheringInfoPerRB-List ::= SEQUENCE (SIZE (1..maxRB)) OF
CipheringInfoPerRB
CipheringInfoPerRB-List-r4 ::= SEQUENCE (SIZE (1..maxRB)) OF
CipheringInfoPerRB-r4
CipheringStatus ::= ENUMERATED {
started, notStarted }
CipheringStatusList-r4 ::= SEQUENCE (SIZE (1..maxCNdomains)) OF
CipheringStatusCNdomain-r4
CipheringStatusCNdomain-r4 ::= SEQUENCE {
cn-DomainIdentity CN-DomainIdentity,
cipheringStatus CipheringStatus,
start-Value START-Value
}
CN-DomainInformation-v390ext ::= SEQUENCE {
cn-DRX-CycleLengthCoeff CN-DRX-CycleLengthCoefficient
}
CN-DomainInformationList-v390ext ::= SEQUENCE (SIZE (1..maxCNdomains)) OF
CN-DomainInformation-v390ext
CompressedModeMeasCapability-r4 ::= SEQUENCE {
fdd-Measurements BOOLEAN,
-- TABULAR: The IEs tdd-Measurements, gsm-Measurements and multiCarrierMeasurements
-- are made optional since they are conditional based on another information element.
-- Their absence corresponds to the case where the condition is not true.
tdd384-Measurements BOOLEAN OPTIONAL,
tdd128-Measurements BOOLEAN OPTIONAL,
gsm-Measurements GSM-Measurements OPTIONAL,
multiCarrierMeasurements BOOLEAN OPTIONAL
}
COUNT-C-List ::= SEQUENCE (SIZE (1..maxCNdomains)) OF
COUNT-CSingle
COUNT-CSingle ::= SEQUENCE {
cn-DomainIdentity CN-DomainIdentity,
count-C BIT STRING (SIZE (32))
}
DL-PhysChCapabilityFDD-r4 ::= SEQUENCE {
-- The IE "maxNoDPCH-PDSCH-Codes" only gives information on the maximum number of DPCH Codes.
maxNoDPCH-PDSCH-Codes INTEGER (1..8),
maxNoPhysChBitsReceived MaxNoPhysChBitsReceived,
supportForSF-512 BOOLEAN,
-- dummy, dummy2 and dummy3 are not used in this version of the specification
-- and if received they should be ignored.
dummy BOOLEAN,
dummy2 SimultaneousSCCPCH-DPCH-Reception,
dummy3 SupportOfDedicatedPilotsForChEstimation OPTIONAL
}
DL-PhysChCapabilityFDD-r5 ::= SEQUENCE {
-- The IE "maxNoDPCH-PDSCH-Codes" only gives information on the maximum number of DPCH Codes.
maxNoDPCH-PDSCH-Codes INTEGER (1..8),
maxNoPhysChBitsReceived MaxNoPhysChBitsReceived,
supportForSF-512 BOOLEAN,
-- dummy, dumy2 and dummy3 are not used in this version of the specification
-- and if received they should be ignored.
dummy BOOLEAN,
dummy2 SimultaneousSCCPCH-DPCH-Reception,
dummy3 SupportOfDedicatedPilotsForChEstimation OPTIONAL,
fdd-hspdsch CHOICE {
supported SEQUENCE {
hsdsch-physical-layer-category HSDSCH-physical-layer-category,
-- dummy and dummy2 are not used in this version of the specification
-- and if received they should be ignored.
dummy BOOLEAN,
dummy2 BOOLEAN
},
unsupported NULL
}
}
DL-PhysChCapabilityTDD-r5 ::= SEQUENCE {
maxTS-PerFrame MaxTS-PerFrame,
maxPhysChPerFrame MaxPhysChPerFrame,
minimumSF MinimumSF-DL,
supportOfPDSCH BOOLEAN,
maxPhysChPerTS MaxPhysChPerTS,
tdd384-hspdsch CHOICE {
supported HSDSCH-physical-layer-category,
unsupported NULL
}
}
DL-PhysChCapabilityTDD-LCR-r5 ::= SEQUENCE {
maxTS-PerSubFrame MaxTS-PerSubFrame-r4,
maxPhysChPerFrame MaxPhysChPerSubFrame-r4,
minimumSF MinimumSF-DL,
supportOfPDSCH BOOLEAN,
maxPhysChPerTS MaxPhysChPerTS,
supportOf8PSK BOOLEAN,
tdd128-hspdsch CHOICE {
supported HSDSCH-physical-layer-category,
unsupported NULL
}
}
DL-RFC3095-Context ::= SEQUENCE {
rfc3095-Context-Identity INTEGER (0..16383),
dl-mode ENUMERATED {u, o, r},
dl-ref-ir OCTET STRING ( SIZE (1..3000)),
dl-ref-time INTEGER (0..4294967295) OPTIONAL,
dl-curr-time INTEGER (0..4294967295) OPTIONAL,
dl-syn-offset-id INTEGER (0..65535) OPTIONAL,
dl-syn-slope-ts INTEGER (0..4294967295) OPTIONAL,
dl-dyn-changed BOOLEAN
}
ImplementationSpecificParams ::= BIT STRING (SIZE (1..512))
IntegrityProtectionStatus ::= ENUMERATED {
started, notStarted }
InterRAT-UE-RadioAccessCapabilityList-r5 ::= SEQUENCE {
interRAT-UE-RadioAccessCapability InterRAT-UE-RadioAccessCapabilityList,
geranIu-RadioAccessCapability GERANIu-RadioAccessCapability OPTIONAL
}
IntraFreqReportingCriteria-r6-ext ::= SEQUENCE {
-- The content of the v690 non-critical extension should be
-- considered as an extension of IE IntraFreqEventCriteriaList
event Event1j-r6,
hysteresis Hysteresis,
timeToTrigger TimeToTrigger,
reportingCellStatus ReportingCellStatus OPTIONAL
}
-- dummy is not used in this version of the specification, it should
-- not be sent and if received it should be ignored.
MaxHcContextSpace-r5 ::= ENUMERATED {
dummy, by1024, by2048, by4096, by8192,
by16384, by32768, by65536, by131072 }
MeasurementCapability-r4 ::= SEQUENCE {
downlinkCompressedMode CompressedModeMeasCapability-r4,
uplinkCompressedMode CompressedModeMeasCapability-r4
}
MeasurementCommandWithType ::= CHOICE {
setup MeasurementType,
modify NULL,
release NULL
}
MeasurementCommandWithType-r4 ::= CHOICE {
setup MeasurementType-r4,
modify NULL,
release NULL
}
MeasurementCommandWithType-r6 ::= CHOICE {
setup MeasurementType-r6,
modify NULL,
release NULL
}
OngoingMeasRep ::= SEQUENCE {
measurementIdentity MeasurementIdentity,
-- TABULAR: The CHOICE Measurement in the tabular description is included
-- in MeasurementCommandWithType
measurementCommandWithType MeasurementCommandWithType,
measurementReportingMode MeasurementReportingMode OPTIONAL,
additionalMeasurementID-List AdditionalMeasurementID-List OPTIONAL
}
OngoingMeasRep-r4 ::= SEQUENCE {
measurementIdentity MeasurementIdentity,
-- TABULAR: The CHOICE Measurement in the tabular description is included
-- in MeasurementCommandWithType-r4.
measurementCommandWithType MeasurementCommandWithType-r4,
measurementReportingMode MeasurementReportingMode OPTIONAL,
additionalMeasurementID-List AdditionalMeasurementID-List OPTIONAL
}
OngoingMeasRep-r5 ::= SEQUENCE {
measurementIdentity MeasurementIdentity,
-- TABULAR: The CHOICE Measurement in the tabular description is included
-- in MeasurementCommandWithType-r4.
measurementCommandWithType MeasurementCommandWithType-r4,
measurementReportingMode MeasurementReportingMode OPTIONAL,
additionalMeasurementID-List AdditionalMeasurementID-List OPTIONAL,
measurementCommand-v590ext CHOICE {
-- the choice "intra-frequency" shall be used for the case of intra-frequency measurement,
-- as well as when intra-frequency events are configured for inter-frequency measurement
intra-frequency Intra-FreqEventCriteriaList-v590ext,
inter-frequency Inter-FreqEventCriteriaList-v590ext
} OPTIONAL,
intraFreqReportingCriteria-1b-r5 IntraFreqReportingCriteria-1b-r5 OPTIONAL,
intraFreqEvent-1d-r5 IntraFreqEvent-1d-r5 OPTIONAL
}
OngoingMeasRep-r6 ::= SEQUENCE {
measurementIdentity MeasurementIdentity,
measurementCommandWithType MeasurementCommandWithType-r6,
measurementReportingMode MeasurementReportingMode OPTIONAL,
additionalMeasurementID-List AdditionalMeasurementID-List OPTIONAL
}
OngoingMeasRep-r7 ::= SEQUENCE {
measurementIdentity MeasurementIdentity,
measurementCommandWithType SEQUENCE {
measurementCommandWithType MeasurementCommandWithType-r6,
thresholdSFN-GPS-TOW-us ThresholdSFN-GPS-TOW-us OPTIONAL
},
measurementReportingMode MeasurementReportingMode OPTIONAL,
additionalMeasurementID-List AdditionalMeasurementID-List OPTIONAL
}
OngoingMeasRepList ::= SEQUENCE (SIZE (1..maxNoOfMeas)) OF
OngoingMeasRep
OngoingMeasRepList-r4 ::= SEQUENCE (SIZE (1..maxNoOfMeas)) OF
OngoingMeasRep-r4
OngoingMeasRepList-r5 ::= SEQUENCE (SIZE (1..maxNoOfMeas)) OF
OngoingMeasRep-r5
OngoingMeasRepList-r6 ::= SEQUENCE (SIZE (1..maxNoOfMeas)) OF
OngoingMeasRep-r6
OngoingMeasRepList-r7 ::= SEQUENCE (SIZE (1..maxNoOfMeas)) OF
OngoingMeasRep-r7
PDCP-Capability-r4 ::= SEQUENCE {
losslessSRNS-RelocationSupport BOOLEAN,
supportForRfc2507 CHOICE {
notSupported NULL,
supported MaxHcContextSpace
},
supportForRfc3095 CHOICE {
notSupported NULL,
supported SEQUENCE {
maxROHC-ContextSessions MaxROHC-ContextSessions-r4 DEFAULT s16,
reverseCompressionDepth INTEGER (0..65535) DEFAULT 0
}
}
}
PDCP-Capability-r5 ::= SEQUENCE {
losslessSRNS-RelocationSupport BOOLEAN,
supportForRfc2507 CHOICE {
notSupported NULL,
supported MaxHcContextSpace-r5
},
supportForRfc3095 CHOICE {
notSupported NULL,
supported SEQUENCE {
maxROHC-ContextSessions MaxROHC-ContextSessions-r4 DEFAULT s16,
reverseCompressionDepth INTEGER (0..65535) DEFAULT 0,
supportForRfc3095ContextRelocation BOOLEAN
}
}
}
PDCP-Capability-r6 ::= SEQUENCE {
losslessSRNS-RelocationSupport BOOLEAN,
losslessDLRLC-PDUSizeChange ENUMERATED { true } OPTIONAL,
supportForRfc2507 CHOICE {
notSupported NULL,
supported MaxHcContextSpace-r5
},
supportForRfc3095 CHOICE {
notSupported NULL,
supported SEQUENCE {
maxROHC-ContextSessions MaxROHC-ContextSessions-r4 DEFAULT s16,
reverseCompressionDepth INTEGER (0..65535) DEFAULT 0,
supportForRfc3095ContextRelocation BOOLEAN
}
}
}
PhysicalChannelCapability-r4 ::= SEQUENCE {
fddPhysChCapability SEQUENCE {
downlinkPhysChCapability DL-PhysChCapabilityFDD-r4,
uplinkPhysChCapability UL-PhysChCapabilityFDD
} OPTIONAL,
tdd384-PhysChCapability SEQUENCE {
downlinkPhysChCapability DL-PhysChCapabilityTDD,
uplinkPhysChCapability UL-PhysChCapabilityTDD
} OPTIONAL,
tdd128-PhysChCapability SEQUENCE {
downlinkPhysChCapability DL-PhysChCapabilityTDD-LCR-r4,
uplinkPhysChCapability UL-PhysChCapabilityTDD-LCR-r4
} OPTIONAL
}
PhysicalChannelCapability-r5 ::= SEQUENCE {
fddPhysChCapability SEQUENCE {
downlinkPhysChCapability DL-PhysChCapabilityFDD-r5,
uplinkPhysChCapability UL-PhysChCapabilityFDD
} OPTIONAL,
tdd384-PhysChCapability SEQUENCE {
downlinkPhysChCapability DL-PhysChCapabilityTDD-r5,
uplinkPhysChCapability UL-PhysChCapabilityTDD
} OPTIONAL,
tdd128-PhysChCapability SEQUENCE {
downlinkPhysChCapability DL-PhysChCapabilityTDD-LCR-r5,
uplinkPhysChCapability UL-PhysChCapabilityTDD-LCR-r4
} OPTIONAL
}
RF-Capability-r4 ::= SEQUENCE {
fddRF-Capability SEQUENCE {
ue-PowerClass UE-PowerClassExt,
txRxFrequencySeparation TxRxFrequencySeparation
} OPTIONAL,
tdd384-RF-Capability SEQUENCE {
ue-PowerClass UE-PowerClassExt,
radioFrequencyBandTDDList RadioFrequencyBandTDDList,
chipRateCapability ChipRateCapability
} OPTIONAL,
tdd128-RF-Capability SEQUENCE {
ue-PowerClass UE-PowerClassExt,
radioFrequencyBandTDDList RadioFrequencyBandTDDList,
chipRateCapability ChipRateCapability
} OPTIONAL
}
RFC3095-ContextInfo ::= SEQUENCE {
rb-Identity RB-Identity,
rfc3095-Context-List RFC3095-Context-List
}
RFC3095-Context-List ::= SEQUENCE (SIZE (1..maxRFC3095-CID)) OF SEQUENCE {
dl-RFC3095-Context DL-RFC3095-Context OPTIONAL,
ul-RFC3095-Context UL-RFC3095-Context OPTIONAL
}
RLC-Capability-r5 ::= SEQUENCE {
totalRLC-AM-BufferSize TotalRLC-AM-BufferSize-r5,
maximumRLC-WindowSize MaximumRLC-WindowSize,
maximumAM-EntityNumber MaximumAM-EntityNumberRLC-Cap
}
SRB-SpecificIntegrityProtInfo ::= SEQUENCE {
ul-RRC-HFN BIT STRING (SIZE (28)),
dl-RRC-HFN BIT STRING (SIZE (28)),
ul-RRC-SequenceNumber RRC-MessageSequenceNumber,
dl-RRC-SequenceNumber RRC-MessageSequenceNumber
}
SRB-SpecificIntegrityProtInfoList ::= SEQUENCE (SIZE (4..maxSRBsetup)) OF
SRB-SpecificIntegrityProtInfo
StateOfRRC ::= ENUMERATED {
cell-DCH, cell-FACH,
cell-PCH, ura-PCH }
StateOfRRC-Procedure ::= ENUMERATED {
awaitNoRRC-Message,
awaitRB-ReleaseComplete,
awaitRB-SetupComplete,
awaitRB-ReconfigurationComplete,
awaitTransportCH-ReconfigurationComplete,
awaitPhysicalCH-ReconfigurationComplete,
awaitActiveSetUpdateComplete,
awaitHandoverComplete,
sendCellUpdateConfirm,
sendUraUpdateConfirm,
-- dummy is not used in this version of specification
-- It should not be sent
dummy,
otherStates
}
TotalRLC-AM-BufferSize-r5 ::= ENUMERATED {
kb10, kb50, kb100, kb150, kb200,
kb300, kb400, kb500, kb750, kb1000 }
TPC-Combination-Info ::= SEQUENCE {
primaryCPICH-Info PrimaryCPICH-Info,
tpc-CombinationIndex TPC-CombinationIndex
}
UE-MultiModeRAT-Capability-r5 ::= SEQUENCE {
multiRAT-CapabilityList MultiRAT-Capability,
multiModeCapability MultiModeCapability,
supportOfUTRAN-ToGERAN-NACC BOOLEAN
}
UE-Positioning-Capability-r4 ::= SEQUENCE {
standaloneLocMethodsSupported BOOLEAN,
ue-BasedOTDOA-Supported BOOLEAN,
networkAssistedGPS-Supported NetworkAssistedGPS-Supported,
supportForUE-GPS-TimingOfCellFrames BOOLEAN,
supportForIPDL BOOLEAN,
rx-tx-TimeDifferenceType2Capable BOOLEAN,
validity-CellPCH-UraPCH ENUMERATED { true } OPTIONAL,
sfn-sfnType2Capability ENUMERATED { true } OPTIONAL
}
UE-Positioning-LastKnownPos ::= SEQUENCE {
sfn INTEGER (0..4095),
cell-id CellIdentity,
positionEstimate PositionEstimate
}
UE-RadioAccessCapability-r4 ::= SEQUENCE {
accessStratumReleaseIndicator AccessStratumReleaseIndicator,
pdcp-Capability PDCP-Capability-r4,
rlc-Capability RLC-Capability,
transportChannelCapability TransportChannelCapability,
rf-Capability RF-Capability-r4,
physicalChannelCapability PhysicalChannelCapability-r4,
ue-MultiModeRAT-Capability UE-MultiModeRAT-Capability,
securityCapability SecurityCapability,
ue-positioning-Capability UE-Positioning-Capability-r4,
measurementCapability MeasurementCapability-r4 OPTIONAL
}
UE-RadioAccessCapability-r5 ::= SEQUENCE {
accessStratumReleaseIndicator AccessStratumReleaseIndicator,
dl-CapabilityWithSimultaneousHS-DSCHConfig
DL-CapabilityWithSimultaneousHS-DSCHConfig OPTIONAL,
pdcp-Capability PDCP-Capability-r5,
rlc-Capability RLC-Capability-r5,
transportChannelCapability TransportChannelCapability,
rf-Capability RF-Capability-r4,
physicalChannelCapability PhysicalChannelCapability-r5,
ue-MultiModeRAT-Capability UE-MultiModeRAT-Capability-r5,
securityCapability SecurityCapability,
ue-positioning-Capability UE-Positioning-Capability-r4,
measurementCapability MeasurementCapability-r4 OPTIONAL
}
UE-RadioAccessCapability-r6 ::= SEQUENCE {
accessStratumReleaseIndicator AccessStratumReleaseIndicator,
dl-CapabilityWithSimultaneousHS-DSCHConfig
DL-CapabilityWithSimultaneousHS-DSCHConfig OPTIONAL,
pdcp-Capability PDCP-Capability-r6,
rlc-Capability RLC-Capability-r5,
transportChannelCapability TransportChannelCapability,
rf-Capability RF-Capability-r4,
physicalChannelCapability PhysicalChannelCapability-r5,
ue-MultiModeRAT-Capability UE-MultiModeRAT-Capability-r5,
securityCapability SecurityCapability,
ue-positioning-Capability UE-Positioning-Capability-r4,
measurementCapability MeasurementCapability-r4 OPTIONAL
}
UE-RadioAccessCapability-r7 ::= SEQUENCE {
accessStratumReleaseIndicator AccessStratumReleaseIndicator,
dl-CapabilityWithSimultaneousHS-DSCHConfig
DL-CapabilityWithSimultaneousHS-DSCHConfig OPTIONAL,
pdcp-Capability PDCP-Capability-r6,
rlc-Capability RLC-Capability-r5,
transportChannelCapability TransportChannelCapability,
rf-Capability RF-Capability-r7,
physicalChannelCapability PhysicalChannelCapability-r7,
ue-MultiModeRAT-Capability UE-MultiModeRAT-Capability-r5,
securityCapability SecurityCapability,
ue-positioning-Capability UE-Positioning-Capability-r4,
measurementCapability MeasurementCapability-r4 OPTIONAL
}
UL-RFC3095-Context ::= SEQUENCE {
rfc3095-Context-Identity INTEGER (0..16383),
ul-mode ENUMERATED {u, o, r},
ul-ref-ir OCTET STRING ( SIZE (1..3000)),
ul-ref-time INTEGER (0..4294967295) OPTIONAL,
ul-curr-time INTEGER (0..4294967295) OPTIONAL,
ul-syn-offset-id INTEGER (0..65535) OPTIONAL,
ul-syn-slope-ts INTEGER (0..4294967295) OPTIONAL,
ul-ref-sn-1 INTEGER (0..65535) OPTIONAL
}
END
|