diff options
author | John Thacker <johnthacker@gmail.com> | 2023-03-02 07:40:23 -0500 |
---|---|---|
committer | John Thacker <johnthacker@gmail.com> | 2023-03-02 17:40:17 +0000 |
commit | 224d8dba97cb63b6096bfb6b9fe19c7c52679c31 (patch) | |
tree | 6f6078c843ae84c5e72ae3934b37e0b9c2c2b222 | |
parent | 36395517d348718ab3af01df9ea058f16a578631 (diff) |
Qt: Sequence diagram comments are not numbers
The comments in the flow diagrams are conceptually an extra y Axis
ticker label on the right. Tell QCustomPlot that we don't want to
render things that look like sufficiently large numbers in scientific
notation.
Fix #18879
-rw-r--r-- | ui/qt/sequence_diagram.cpp | 3 |
1 files changed, 3 insertions, 0 deletions
diff --git a/ui/qt/sequence_diagram.cpp b/ui/qt/sequence_diagram.cpp index 702f1f13ce..4628915b1a 100644 --- a/ui/qt/sequence_diagram.cpp +++ b/ui/qt/sequence_diagram.cpp @@ -55,6 +55,9 @@ SequenceDiagram::SequenceDiagram(QCPAxis *keyAxis, QCPAxis *valueAxis, QCPAxis * // yaxis2 (comment): Extra info ("Comment" in GTK+) // valueAxis->setAutoTickStep(false); + + /* The comments are not numbers, don't try to pretty print exponentials. */ + commentAxis->setNumberFormat("f"); QList<QCPAxis *> axes; axes << value_axis_ << key_axis_ << comment_axis_; QPen no_pen(Qt::NoPen); |