diff options
author | Jacob Erlbeck <jerlbeck@sysmocom.de> | 2015-06-09 09:44:36 +0200 |
---|---|---|
committer | Jacob Erlbeck <jerlbeck@sysmocom.de> | 2015-06-22 10:39:06 +0200 |
commit | 94cde130ca78d6ca1b5f815180ccdd363b234407 (patch) | |
tree | e7443307dd30847d4d6c7bffad99c8a2023b8b7a /src/sysmo_l1_fwd.c | |
parent | e4bcb62dbf89bf882805e3824251a3013f3eecd7 (diff) |
ms: Add UL CS selection based on L1 link quality
Currently the UL CS values are set to the corresponding DL CS value,
eventually limited by a maximum value. This approach does not reflect
the general situation of the RF link between ME and BTS, which is
rather asymmetric e.g. due to a lower degree of TX efficiency of the
built-in antenna. This means, that UL and DL CS control should be
decoupled for better results.
This commit adds automatic UL CS selection based on the link quality
measurement parameter. Each coding scheme is mapped to a link quality
range. If the link quality value leaves that range, the current UL CS
value is increased/decreased accordingly. This value will be copied
when the next PACKET_UPLINK_ACK_NACK or PACKET_UPLINK_ASSIGMENT is
sent to the MS.
The following VTY command will be added to the config-pcu node:
- cs link-quality-ranges cs1 <0-35> cs2 <0-35> <0-35>
cs3 <0-35> <0-35> cs4 <0-35>
which sets the ranges for the four coding schemes. For instance the
example below reflects the current default values:
cs link-quality-ranges cs1 6 cs2 5 8 cs3 7 13 cs4 12
set the following ranges, where the overlapping is used to configure
a hysteresis:
CS1: -inf .. 6
CS2: 5 .. 8
CS3: 7 .. 13
CS4: 12 .. inf
Sponsored-by: On-Waves ehf