diff options
author | Vadim Yanitskiy <vyanitskiy@sysmocom.de> | 2020-07-06 15:25:27 +0700 |
---|---|---|
committer | fixeria <vyanitskiy@sysmocom.de> | 2020-07-21 19:46:56 +0000 |
commit | d3ce838e0c9995179e20b7e0f1bae14cbad9fc32 (patch) | |
tree | 11eb4cd8ccecdde9f5024ac6beeb1fc38241b554 | |
parent | e6e2b066890efc2cba490fd9ee00b42332c79211 (diff) |
ttcn3-bts-test/osmo-bsc.cfg: change pchan config for TRX#1..3
The new physical channel configuration will be used in the upcoming
multi-transceiver test cases. Rather than having the same logical
channel combinations configured for all transceivers, it makes
sense to test more deviations. TRX#0 has kept unchanged.
== Physical channel configuration ==
+-------+------------------+------------------+------------------+------------------+
| # / # | TRX#0 | TRX#1 | TRX#2 | TRX#3 |
+-------+------------------+------------------+------------------+------------------+
| TS0 | CCCH+SDCCH4 | TCH/F | TCH/H | PDCH |
+-------+------------------+------------------+------------------+------------------+
| TS1 | TCH/F | SDCCH8+CBCH | PDCH | TCH/H |
+-------+------------------+------------------+------------------+------------------+
| TS2 | TCH/F | PDCH | SDCCH8+CBCH | TCH/H |
+-------+------------------+------------------+------------------+------------------+
| TS3 | TCH/F_PDCH | TCH/F_TCH/H_PDCH | PDCH | SDCCH8+CBCH |
+-------+------------------+------------------+------------------+------------------+
| TS4 | TCH/F_TCH/H_PDCH | TCH/F_PDCH | SDCCH8 | PDCH |
+-------+------------------+------------------+------------------+------------------+
| TS5 | TCH/H | SDCCH8 | TCH/F | TCH/F |
+-------+------------------+------------------+------------------+------------------+
| TS6 | SDCCH8 | PDCH | PDCH | PDCH |
+-------+------------------+------------------+------------------+------------------+
| TS7 | PDCH | PDCH | PDCH | SDCCH8 |
+-------+------------------+------------------+------------------+------------------+
Change-Id: Ib27704dcba3979d69e44065c472b1452eaa11a7a
Related: SYS#4868, OS#4546
-rw-r--r-- | ttcn3-bts-test/osmo-bsc.cfg | 44 |
1 files changed, 22 insertions, 22 deletions
diff --git a/ttcn3-bts-test/osmo-bsc.cfg b/ttcn3-bts-test/osmo-bsc.cfg index 1dcf226..f1d2315 100644 --- a/ttcn3-bts-test/osmo-bsc.cfg +++ b/ttcn3-bts-test/osmo-bsc.cfg @@ -148,25 +148,25 @@ network max_power_red 20 rsl e1 tei 1 timeslot 0 - phys_chan_config SDCCH8 + phys_chan_config TCH/F hopping enabled 0 timeslot 1 - phys_chan_config TCH/F + phys_chan_config SDCCH8+CBCH hopping enabled 0 timeslot 2 - phys_chan_config TCH/F + phys_chan_config PDCH hopping enabled 0 timeslot 3 - phys_chan_config TCH/F_PDCH + phys_chan_config TCH/F_TCH/H_PDCH hopping enabled 0 timeslot 4 - phys_chan_config TCH/F_TCH/H_PDCH + phys_chan_config TCH/F_PDCH hopping enabled 0 timeslot 5 - phys_chan_config TCH/H + phys_chan_config SDCCH8 hopping enabled 0 timeslot 6 - phys_chan_config SDCCH8 + phys_chan_config PDCH hopping enabled 0 timeslot 7 phys_chan_config PDCH @@ -178,25 +178,25 @@ network max_power_red 20 rsl e1 tei 2 timeslot 0 - phys_chan_config SDCCH8 + phys_chan_config TCH/H hopping enabled 0 timeslot 1 - phys_chan_config TCH/F + phys_chan_config PDCH hopping enabled 0 timeslot 2 - phys_chan_config TCH/F + phys_chan_config SDCCH8+CBCH hopping enabled 0 timeslot 3 - phys_chan_config TCH/F_PDCH + phys_chan_config PDCH hopping enabled 0 timeslot 4 - phys_chan_config TCH/F_TCH/H_PDCH + phys_chan_config SDCCH8 hopping enabled 0 timeslot 5 - phys_chan_config TCH/H + phys_chan_config TCH/F hopping enabled 0 timeslot 6 - phys_chan_config SDCCH8 + phys_chan_config PDCH hopping enabled 0 timeslot 7 phys_chan_config PDCH @@ -208,28 +208,28 @@ network max_power_red 20 rsl e1 tei 3 timeslot 0 - phys_chan_config SDCCH8 + phys_chan_config PDCH hopping enabled 0 timeslot 1 - phys_chan_config TCH/F + phys_chan_config TCH/H hopping enabled 0 timeslot 2 - phys_chan_config TCH/F + phys_chan_config TCH/H hopping enabled 0 timeslot 3 - phys_chan_config TCH/F_PDCH + phys_chan_config SDCCH8+CBCH hopping enabled 0 timeslot 4 - phys_chan_config TCH/F_TCH/H_PDCH + phys_chan_config PDCH hopping enabled 0 timeslot 5 - phys_chan_config TCH/H + phys_chan_config TCH/F hopping enabled 0 timeslot 6 - phys_chan_config SDCCH8 + phys_chan_config PDCH hopping enabled 0 timeslot 7 - phys_chan_config PDCH + phys_chan_config SDCCH8 hopping enabled 0 msc 0 core-location-area-code 666 |