diff options
Diffstat (limited to 'asn1/x721/Attribute-ASN1Module.asn')
-rw-r--r-- | asn1/x721/Attribute-ASN1Module.asn | 533 |
1 files changed, 0 insertions, 533 deletions
diff --git a/asn1/x721/Attribute-ASN1Module.asn b/asn1/x721/Attribute-ASN1Module.asn deleted file mode 100644 index e4c0b5adaa..0000000000 --- a/asn1/x721/Attribute-ASN1Module.asn +++ /dev/null @@ -1,533 +0,0 @@ --- Module Attribute-ASN1Module (X.721:02/1992) -Attribute-ASN1Module {joint-iso-itu-t ms(9) smi(3) part2(2) asn1Module(2) 1} -DEFINITIONS IMPLICIT TAGS ::= -BEGIN - ---EXPORTS everything -IMPORTS - CMIP-ATTRIBUTE, AttributeSet, DistinguishedName, CMISFilter, Attribute, - BaseManagedObjectId, AttributeId, ObjectInstance, ObjectClass, EventTypeId - FROM CMIP-1 {joint-iso-itu-t ms(9) cmip(1) modules(0) protocol(3)} - AE-title - FROM ACSE-1 {joint-iso-itu-t association-control(2) modules(0) apdus(0) - version1(1)}; - --- Note that the syntax of AE-title to be used is from CCITT Rec. X.227 | ISO 8650 corrigendum and --- not "ANY". -smi2AttributeID OBJECT IDENTIFIER ::= - {joint-iso-itu-t ms(9) smi(3) part2(2) attribute(7)} - -smi2AttributeGroup OBJECT IDENTIFIER ::= - {joint-iso-itu-t ms(9) smi(3) part2(2) attributeGroup(8)} - -DMI-TYPE-IDENTIFIER ::= CLASS {&id OBJECT IDENTIFIER UNIQUE, - &Value -}WITH SYNTAX {TYPE &Value - ID &id -} --- as2wrs fault fix: -DMI-EXTENSION::= CLASS {&id OBJECT IDENTIFIER UNIQUE, - &Value -}WITH SYNTAX {TYPE &Value - ID &id -} --- as2wrs fault fix: -DMI-SERVICEUSER ::= CLASS {&id OBJECT IDENTIFIER UNIQUE, - &Value -}WITH SYNTAX {TYPE &Value - ID &id -} - --- as2wrs fault fix: -DMI-SUPPORTEDFEATURES ::= CLASS {&id OBJECT IDENTIFIER UNIQUE, - &Value -}WITH SYNTAX {TYPE &Value - ID &id -} - --- The value assignments for the probable cause used in CCITT Rec. X.733 | ISO/IEC 10164-4 are specified --- below. --- These are specified in accordance with the corrigendum to ASN.1 ISO/IEC JTC1/SC21 N5901 -arfProbableCause OBJECT IDENTIFIER ::= - {joint-iso-ccitt ms(9) smi(3) part2(2) standardSpecificExtension(0) arf(0)} - -adapterError ProbableCause ::= globalValue:{arfProbableCause 1} - -applicationSubsystemFailure ProbableCause ::= globalValue:{arfProbableCause 2} - -bandwidthReduced ProbableCause ::= globalValue:{arfProbableCause 3} - -callEstablishmentError ProbableCause ::= globalValue:{arfProbableCause 4} - -communicationsProtocolError ProbableCause ::= globalValue:{arfProbableCause 5} - -communicationsSubsystemFailure ProbableCause ::= - globalValue:{arfProbableCause 6} - -configurationOrCustomizationError ProbableCause ::= - globalValue:{arfProbableCause 7} - -congestion ProbableCause ::= globalValue:{arfProbableCause 8} - -corruptData ProbableCause ::= globalValue:{arfProbableCause 9} - -cpuCyclesLimitExceeded ProbableCause ::= globalValue:{arfProbableCause 10} - -dataSetOrModemError ProbableCause ::= globalValue:{arfProbableCause 11} - -degradedSignal ProbableCause ::= globalValue:{arfProbableCause 12} - -dTE-DCEInterfaceError ProbableCause ::= globalValue:{arfProbableCause 13} - -enclosureDoorOpen ProbableCause ::= globalValue:{arfProbableCause 14} - -equipmentMalfunction ProbableCause ::= globalValue:{arfProbableCause 15} - -excessiveVibration ProbableCause ::= globalValue:{arfProbableCause 16} - -fileError ProbableCause ::= globalValue:{arfProbableCause 17} - -fireDetected ProbableCause ::= globalValue:{arfProbableCause 18} - -floodDetected ProbableCause ::= globalValue:{arfProbableCause 19} - -framingError ProbableCause ::= globalValue:{arfProbableCause 20} - -heatingOrVentilationOrCoolingSystemProblem ProbableCause ::= - globalValue:{arfProbableCause 21} - -humidityUnacceptable ProbableCause ::= globalValue:{arfProbableCause 22} - -inputOutputDeviceError ProbableCause ::= globalValue:{arfProbableCause 23} - -inputDeviceError ProbableCause ::= globalValue:{arfProbableCause 24} - -lANError ProbableCause ::= globalValue:{arfProbableCause 25} - -leakDetected ProbableCause ::= globalValue:{arfProbableCause 26} - -localNodeTransmissionError ProbableCause ::= globalValue:{arfProbableCause 27} - -lossOfFrame ProbableCause ::= globalValue:{arfProbableCause 28} - -lossOfSignal ProbableCause ::= globalValue:{arfProbableCause 29} - -materialSupplyExhausted ProbableCause ::= globalValue:{arfProbableCause 30} - -multiplexerProblem ProbableCause ::= globalValue:{arfProbableCause 31} - -outOfMemory ProbableCause ::= globalValue:{arfProbableCause 32} - -ouputDeviceError ProbableCause ::= globalValue:{arfProbableCause 33} - -performanceDegraded ProbableCause ::= globalValue:{arfProbableCause 34} - -powerProblem ProbableCause ::= globalValue:{arfProbableCause 35} - -pressureUnacceptable ProbableCause ::= globalValue:{arfProbableCause 36} - -processorProblem ProbableCause ::= globalValue:{arfProbableCause 37} - -pumpFailure ProbableCause ::= globalValue:{arfProbableCause 38} - -queueSizeExceeded ProbableCause ::= globalValue:{arfProbableCause 39} - -receiveFailure ProbableCause ::= globalValue:{arfProbableCause 40} - -receiverFailure ProbableCause ::= globalValue:{arfProbableCause 41} - -remoteNodeTransmissionError ProbableCause ::= globalValue:{arfProbableCause 42} - -resourceAtOrNearingCapacity ProbableCause ::= globalValue:{arfProbableCause 43} - -responseTimeExcessive ProbableCause ::= globalValue:{arfProbableCause 44} - -retransmissionRateExcessive ProbableCause ::= globalValue:{arfProbableCause 45} - -softwareError ProbableCause ::= globalValue:{arfProbableCause 46} - -softwareProgramAbnormallyTerminated ProbableCause ::= - globalValue:{arfProbableCause 47} - -softwareProgramError ProbableCause ::= globalValue:{arfProbableCause 48} - -storageCapacityProblem ProbableCause ::= globalValue:{arfProbableCause 49} - -temperatureUnacceptable ProbableCause ::= globalValue:{arfProbableCause 50} - -thresholdCrossed ProbableCause ::= globalValue:{arfProbableCause 51} - -timingProblem ProbableCause ::= globalValue:{arfProbableCause 52} - -toxicLeakDetected ProbableCause ::= globalValue:{arfProbableCause 53} - -transmitFailure ProbableCause ::= globalValue:{arfProbableCause 54} - -transmitterFailure ProbableCause ::= globalValue:{arfProbableCause 55} - -underlyingResourceUnavailable ProbableCause ::= - globalValue:{arfProbableCause 56} - -versionMismatch ProbableCause ::= globalValue:{arfProbableCause 57} - --- The following applies to CCITT applications only. --- The use of the following values is subject to 8.1.2.12 of The Alarm Management Function --- (CCITT Recommendation X.733 | 10164-4). -arfProposedRepairAction OBJECT IDENTIFIER ::= - {joint-iso-ccitt ms(9) smi(3) part2(2) standardSpecificExtension(0) arfpra(2)} - -noActionRequired OBJECT IDENTIFIER ::= {arfProposedRepairAction 1} - -repairActionRequired OBJECT IDENTIFIER ::= {arfProposedRepairAction 2} - --- The value assignments for the security alarm cause used in CCITT Rec. X.736 | ISO/IEC 10164-7 are --- specified below. -securityAlarmCause OBJECT IDENTIFIER ::= - {joint-iso-ccitt ms(9) smi(3) part2(2) standardSpecificExtension(0) sarf(1)} - -authenticationFailure SecurityAlarmCause ::= {securityAlarmCause 1} - -breachOfConfidentiality SecurityAlarmCause ::= {securityAlarmCause 2} - -cableTamper SecurityAlarmCause ::= {securityAlarmCause 3} - -delayedInformation SecurityAlarmCause ::= {securityAlarmCause 4} - -denialOfService SecurityAlarmCause ::= {securityAlarmCause 5} - -duplicateInformation SecurityAlarmCause ::= {securityAlarmCause 6} - -informationMissing SecurityAlarmCause ::= {securityAlarmCause 7} - -informationModificationDetected SecurityAlarmCause ::= {securityAlarmCause 8} - -informationOutOfSequence SecurityAlarmCause ::= {securityAlarmCause 9} - -intrusionDetection SecurityAlarmCause ::= {securityAlarmCause 10} - -keyExpired SecurityAlarmCause ::= {securityAlarmCause 11} - -nonRepudiationFailure SecurityAlarmCause ::= {securityAlarmCause 12} - -outOfHoursActivity SecurityAlarmCause ::= {securityAlarmCause 13} - -outOfService SecurityAlarmCause ::= {securityAlarmCause 14} - -proceduralError SecurityAlarmCause ::= {securityAlarmCause 15} - -unauthorizedAccessAttempt SecurityAlarmCause ::= {securityAlarmCause 16} - -unexpectedInformation SecurityAlarmCause ::= {securityAlarmCause 17} - -unspecifiedReason SecurityAlarmCause ::= {securityAlarmCause 18} - --- default value definitions --- asn2wrs Problem omit this assignment ---defaultIntervalsOfDay IntervalsOfDay ::= { --- {intervalStart {hour 0, minute 0}, --- intervalEnd {hour 23, minute 59}} ---} - ---defaultStopTime StopTime ::= continual:NULL - ---defaultWeekMask WeekMask ::= { --- {daysOfWeek '1111111'B, --- intervalsOfDay defaultIntervalsOfDay} ---} - -defaultDiscriminatorConstruct DiscriminatorConstruct ::= and:{} - --- supporting productions -ActiveDestination ::= - Destination(WITH COMPONENTS { - single PRESENT, - multiple ABSENT - }) - -AdditionalText ::= GraphicString - -AdditionalInformation ::= SET OF ManagementExtension - -Allomorphs ::= SET OF ObjectClass - -AdministrativeState ::= ENUMERATED {locked(0), unlocked(1), shuttingDown(2)} - -AttributeIdentifierList ::= SET OF AttributeId - -AttributeList ::= SET OF Attribute - -AttributeValueChangeDefinition ::= - SET OF - SEQUENCE {attributeId CMIP-ATTRIBUTE.&id({AttributeSet}), - oldAttributeValue - [1] CMIP-ATTRIBUTE.&Value({AttributeSet}{@.attributeId}) - OPTIONAL, - newAttributeValue - [2] CMIP-ATTRIBUTE.&Value({AttributeSet}{@.attributeId}) - } - -AlarmStatus ::= - SET OF - INTEGER {underRepair(0), critical(1), major(2), minor(3), - alarmOutstanding(4)} - -AvailabilityStatus ::= - SET OF - INTEGER {inTest(0), failed(1), powerOff(2), offLine(3), offDuty(4), - dependency(5), degraded(6), notInstalled(7), logFull(8)} - --- logFull is defined in CCITT Rec X.735 | ISO/IEC 10164-6. -BackedUpStatus ::= BOOLEAN - --- True implies backed up --- False implies not backed up -BackUpDestinationList ::= SEQUENCE OF AE-title - -BackUpRelationshipObject ::= CHOICE { - objectName ObjectInstance, - noObject NULL -} - -CapacityAlarmThreshold ::= SET OF INTEGER(0..100) - -ConfirmedMode ::= BOOLEAN - --- True implies the mode for event report is confirmed -ControlStatus ::= - SET OF - INTEGER {subjectToTest(0), partOfServicesLocked(1), reservedForTest(2), - suspended(3)} - --- Count ::= INTEGER - -CounterThreshold ::= - SET OF - SEQUENCE {comparisonLevel INTEGER, - offsetValue INTEGER, - notificationOnOff BOOLEAN} - -CorrelatedNotifications ::= - SET OF - SEQUENCE {correlatedNotifications SET OF NotificationIdentifier, - sourceObjectInst ObjectInstance OPTIONAL} - -CurrentLogSize ::= INTEGER - -Destination ::= CHOICE {single AE-title, - multiple SET OF AE-title -} - --- Note that the syntax of AE-title to be used is from CCITT X.227 | ISO 8650 Technical --- corrigendum 1 and not "ANY". -DiscriminatorConstruct ::= - CMISFilter - -EventTime ::= GeneralizedTime - -GaugeThreshold ::= - SET OF SEQUENCE {notifyLow NotifyThreshold, - notifyHigh NotifyThreshold} - -GaugeThresholdValue ::= ObservedValue - --- same choice must be chosen within a sequence --- for both GenericOldState and GenericNewState. -GroupObjects ::= SET OF ObjectInstance - -IntervalsOfDay ::= - SET OF - SEQUENCE {intervalStart Time24, -- start at the beginning of this minute - intervalEnd Time24} -- stop at the end of this minute - -LifecycleState ::= ENUMERATED {planned(0), installed(1), pendingRemoval(2)} - -LogAvailability ::= AvailabilityStatus(WITH COMPONENT (logFull | offDuty)) - -LogFullAction ::= ENUMERATED {wrap(0), halt(1)} - -LoggingTime ::= GeneralizedTime - -LogRecordId ::= - SimpleNameType(WITH COMPONENTS { - number PRESENT, - string ABSENT - }) - -MaxLogSize ::= INTEGER {unlimited(0)} -- size in octets - --- as2wrs fault fix: ---DMI-EXTENSION ::= DMI-TYPE-IDENTIFIER - -ManagementExtension ::= SEQUENCE { - identifier DMI-EXTENSION.&id({ManagementExtensionSet}), - significance [1] BOOLEAN DEFAULT FALSE, - information - [2] DMI-EXTENSION.&Value({ManagementExtensionSet}{@.identifier}) -} - -ManagementExtensionSet DMI-EXTENSION ::= - {...} - -MonitoredAttributes ::= SET OF Attribute - -NameBinding ::= OBJECT IDENTIFIER - -NotificationIdentifier ::= INTEGER -- reuse only when no requirement exists - --- for correlating prior notification. -NotifyThreshold ::= SEQUENCE {threshold ObservedValue, - notifyOnOff BOOLEAN -} - -NumberOfRecords ::= INTEGER - -ObservedValue ::= CHOICE {integer INTEGER, - real REAL -} - -OperationalState ::= ENUMERATED {disabled(0), enabled(1)} - -Packages ::= SET OF OBJECT IDENTIFIER - -PerceivedSeverity ::= ENUMERATED { - indeterminate(0), - -- used when it is not possible to assign the following values - critical(1), major(2), minor(3), warning(4), cleared(5)} - -PrioritisedObject ::= - SET OF - SEQUENCE {object ObjectInstance, - priority INTEGER {highest(0), lowest(127)}} - -ProbableCause ::= CHOICE {globalValue OBJECT IDENTIFIER, - localValue INTEGER -} - --- The values for the probable cause defined in CCITT Rec X.733 | ISO/IEC 10164-4 are specified --- above. -ProceduralStatus ::= - SET OF - INTEGER {initializationRequired(0), notInitialized(1), initializing(2), - reporting(3), terminating(4)} - -ProposedRepairActions ::= SET OF SpecificIdentifier - -SchedulingAvailability ::= AvailabilityStatus(WITH COMPONENT (offDuty)) - -SecurityAlarmCause ::= OBJECT IDENTIFIER - -SecurityAlarmSeverity ::= - PerceivedSeverity(indeterminate | critical | major | minor | warning) - -SecurityAlarmDetector ::= CHOICE { - mechanism [0] OBJECT IDENTIFIER, - object [1] ObjectInstance, - application [2] AE-title -} - -ServiceProvider ::= ServiceUser - --- DMI-SERVICEUSER ::= DMI-TYPE-IDENTIFIER - -ServiceUser ::= SEQUENCE { - identifier DMI-SERVICEUSER.&id({ServiceUserSet}), - details DMI-SERVICEUSER.&Value({ServiceUserSet}{@.identifier}) -} - -ServiceUserSet DMI-SERVICEUSER ::= - {...} - -SimpleNameType ::= CHOICE {number INTEGER, - string GraphicString -} - -SpecificIdentifier ::= CHOICE {oi OBJECT IDENTIFIER, - int INTEGER -} - -SourceIndicator ::= ENUMERATED { - resourceOperation(0), managementOperation(1), unknown(2)} - -SpecificProblems ::= SET OF SpecificIdentifier - -StandbyStatus ::= INTEGER {hotStandby(0), coldStandby(1), providingService(2)} - -StartTime ::= GeneralizedTime - -StopTime ::= CHOICE {specific GeneralizedTime, - continual NULL -} - --- DMI-SUPPORTEDFEATURES ::= DMI-TYPE-IDENTIFIER - -SupportedFeatures ::= - SET OF - SEQUENCE {featureIdentifier - DMI-SUPPORTEDFEATURES.&id({SupportedFeaturesSet}), - featureInfo - DMI-SUPPORTEDFEATURES.&Value - ({SupportedFeaturesSet}{@.featureIdentifier})} - -SupportedFeaturesSet DMI-SUPPORTEDFEATURES ::= - {...} - -SystemId ::= CHOICE {name GraphicString, - number INTEGER, - nothing NULL -} - -SystemTitle ::= CHOICE { - distinguishedName DistinguishedName, - oid OBJECT IDENTIFIER, - nothing NULL -} - -TideMarkInfo ::= SEQUENCE { - currentTideMark TideMark, - previousTideMark TideMark, - resetTime GeneralizedTime -} - -TideMark ::= CHOICE { - maxTideMar [0] ObservedValue, - minTideMark [1] ObservedValue -} - -Time24 ::= SEQUENCE {hour INTEGER(0..23), - minute INTEGER(0..59) -} - -ThresholdInfo ::= SEQUENCE { - triggeredThreshold AttributeId, - observedValue ObservedValue, - thresholdLevel [1] ThresholdLevelInd OPTIONAL, - -- Indication needed for multilevel thresholds - armTime [2] GeneralizedTime OPTIONAL -} - -ThresholdLevelInd ::= CHOICE { - up [1] SEQUENCE {high ObservedValue, - low ObservedValue OPTIONAL}, -- up is the only permitted choice for counter - down [2] SEQUENCE {high ObservedValue, - low ObservedValue} -} - -TrendIndication ::= ENUMERATED {lessSevere(0), noChange(1), moreSevere(2)} - -UnknownStatus ::= BOOLEAN -- TRUE implies unknown status - -UnscheduledLogAvailability ::= AvailabilityStatus(WITH COMPONENT (logFull)) - -UsageState ::= ENUMERATED {idle(0), active(1), busy(2)} - -WeekMask ::= - SET OF - SEQUENCE {daysOfWeek - BIT STRING {sunday(0), monday(1), tuesday(2), wednesday(3), - thursday(4), friday(5), saturday(6)}(SIZE (7)), - intervalsOfDay IntervalsOfDay} - -END -- end of supporting productions - --- Generated by Asnp, the ASN.1 pretty-printer of France Telecom R&D - |