diff options
author | Stephen Fisher <steve@stephen-fisher.com> | 2010-08-16 17:19:42 +0000 |
---|---|---|
committer | Stephen Fisher <steve@stephen-fisher.com> | 2010-08-16 17:19:42 +0000 |
commit | a81a8dd250d7f8668fd122832dac6ea497dcd249 (patch) | |
tree | 6150da8e73fcf1f924639f6dbb19986098f21d47 /epan/dissectors/packet-ndp.c | |
parent | cd67ad0047aaeb4199cbf546800e386d024a4420 (diff) |
Modernize the SONMP ("SynOptics Network Management Protocol") dissector by renaming it to NDP ("Nortel Discovery Protocol") and do some basic cleanup.
svn path=/trunk/; revision=33815
Diffstat (limited to 'epan/dissectors/packet-ndp.c')
-rw-r--r-- | epan/dissectors/packet-ndp.c | 388 |
1 files changed, 388 insertions, 0 deletions
diff --git a/epan/dissectors/packet-ndp.c b/epan/dissectors/packet-ndp.c new file mode 100644 index 0000000000..92e4933270 --- /dev/null +++ b/epan/dissectors/packet-ndp.c @@ -0,0 +1,388 @@ +/* packet-ndp.c +* Routines for the disassembly of the Nortel Discovery Protocol, formerly +* the SynOptics Network Management Protocol (SONMP). +* (c) Copyright Giles Scott <giles.scott1 [AT] arubanetworks.com> +* +* $Id$ +* +* Wireshark - Network traffic analyzer +* By Gerald Combs <gerald@wireshark.org> +* Copyright 1998 Gerald Combs +* +* This program is free software; you can redistribute it and/or +* modify it under the terms of the GNU General Public License +* as published by the Free Software Foundation; either version 2 +* of the License, or (at your option) any later version. +* +* This program is distributed in the hope that it will be useful, +* but WITHOUT ANY WARRANTY; without even the implied warranty of +* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the +* GNU General Public License for more details. +* +* You should have received a copy of the GNU General Public License +* along with this program; if not, write to the Free Software +* Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA. +* +* This protocol has gone by many names over the years: +* +* Bay Discovery Protocol (BDP), Bay Topology Protocol, Bay Network Management +* Protocol (BNMP), Nortel Management MIB (NMM), Nortel Topology Discovery +* Protocol (NTDP), SynOptics Network Management Protocol (SONMP). +* (source: Wikipedia article on "Nortel Discovery Protocol") +* +*/ + +#include "config.h" + +#ifdef HAVE_SYS_TYPES_H +#include <sys/types.h> +#endif + +#include <stdlib.h> + +#include <glib.h> +#include <epan/packet.h> +#include <epan/nlpid.h> + +/* Although this protocol is propietary it is documented in the SynOptics MIB's +* So I'm not giving anything away :-) +* The only thing I have not done is decode the segment identifier; +* This changes so much depending on whether the chassis supports +* multi-segment autotopology. As the 5000 is now EOL don't see much point. +* +* MIB's s5emt104.mib, s5tcs112.mib, synro199.mib these should be available via +* http://www.nortelnetworks.com +*/ + + +/* chassis types */ +/* Last updated from version 229 ("200609010000Z") of SnpxChassisType in SYNOPTICS-ROOT-MIB.mib */ +static const value_string ndp_chassis_val[] = +{ + {1, "other"}, + {2, "3000"}, + {3, "3030"}, + {4, "2310"}, + {5, "2810"}, + {6, "2912"}, + {7, "2914"}, + {8, "271x"}, + {9, "2813"}, + {10, "2814"}, + {11, "2915"}, + {12, "5000"}, + {13, "2813SA"}, + {14, "2814SA"}, + {15, "810M"}, + {16, "Ethercell"}, + {17, "5005"}, + {18, "Alcatel Ethernet workgroup conc."}, + {20, "2715SA"}, + {21, "2486"}, + {22, "28000 series"}, + {23, "23000 series"}, + {24, "5DN00x series"}, + {25, "BayStack Ethernet"}, + {26, "23100 series"}, + {27, "100Base-T Hub"}, + {28, "3000 Fast Ethernet"}, + {29, "Orion switch"}, + /* 30 is "not used" */ + {31, "DDS"}, + {32, "Centillion (6 slot)"}, + {33, "Centillion (12 slot)"}, + {34, "Centillion (1 slot)"}, + {35, "BayStack 301"}, + {36, "BayStack TokenRing Hub"}, + {37, "FVC Multimedia Switch"}, + {38, "Switch Node"}, + {39, "BayStack 302 Switch"}, + {40, "BayStack 350 Switch"}, + {41, "BayStack 150 Ethernet Hub"}, + {42, "Centillion 50N switch"}, + {43, "Centillion 50T switch"}, + {44, "BayStack 303 and 304 Switches"}, + {45, "BayStack 200 Ethernet Hub"}, + {46, "BayStack 250 10/100 Ethernet Hub"}, + /*{47, "StackProbe"}, XXX - No longer listed */ + {48, "BayStack 450 10/100/1000 Switches"}, + {49, "BayStack 410 10/100 Switches"}, + {50, "Passport 1200 L3 Switch"}, + {51, "Passport 1250 L3 Switch"}, + {52, "Passport 1100 L3 Switch"}, + {53, "Passport 1150 L3 Switch"}, + {54, "Passport 1050 L3 Switch"}, + {55, "Passport 1051 L3 Switch"}, + {56, "Passport 8610 L3 Switch"}, + {57, "Passport 8606 L3 Switch"}, + {58, "Passport 8010"}, + {59, "Passport 8006"}, + {60, "BayStack 670 wireless access point"}, + {61, "Passport 740"}, + {62, "Passport 750"}, + {63, "Passport 790"}, + {64, "Business Policy Switch 2000 10/100 Switches"}, + {65, "Passport 8110 L2 Switch"}, + {66, "Passport 8106 L2 Switch"}, + {67, "BayStack 3580 Gig Switch"}, + {68, "BayStack 10 Power Supply Unit"}, + {69, "BayStack 420 10/100 Switch"}, + {70, "OPTera Metro 1200 Ethernet Service Module"}, + {71, "OPTera 8010co"}, + {72, "OPTera 8610co L3 switch"}, + {73, "OPTera 8110co L2 switch"}, + {74, "OPTera 8003"}, + {75, "OPTera 8603 L3 switch"}, + {76, "OPTera 8103 L2 switch"}, + {77, "BayStack 380 10/100/1000 Switch"}, + {78, "Ethernet Switch 470-48T"}, + {79, "OPTera Metro 1450 Ethernet Service Module"}, + {80, "OPTera Metro 1400 Ethernet Service Module"}, + {81, "Alteon Switch Family"}, + {82, "Ethernet Switch 460-24T-PWR"}, + {83, "OPTera Metro 8010 OPM L2 Switch"}, + {84, "OPTera Metro 8010co OPM L2 Switch"}, + {85, "OPTera Metro 8006 OPM L2 Switch"}, + {86, "OPTera Metro 8003 OPM L2 Switch"}, + {87, "Alteon 180e"}, + {88, "Alteon AD3"}, + {89, "Alteon 184"}, + {90, "Alteon AD4"}, + {91, "Passport 1424 L3 switch"}, + {92, "Passport 1648 L3 switch"}, + {93, "Passport 1612 L3 switch"}, + {94, "Passport 1624 L3 switch"}, + {95, "BayStack 380-24F Fiber 1000 Switch"}, + {96, "Ethernet Routing Switch 5510-24T"}, + {97, "Ethernet Routing Switch 5510-48T"}, + {98, "Ethernet Switch 470-24T"}, + {99, "Nortel Networks Wireless LAN Access Point 2220"}, + {100, "Passport RBS 2402 L3 switch"}, + {101, "Alteon Application Switch 2424"}, + {102, "Alteon Application Switch 2224"}, + {103, "Alteon Application Switch 2208"}, + {104, "Alteon Application Switch 2216"}, + {105, "Alteon Application Switch 3408"}, + {106, "Alteon Application Switch 3416"}, + {107, "Nortel Networks Wireless LAN SecuritySwitch 2250"}, + {108, "Ethernet Switch 425-48T"}, + {109, "Ethernet Switch 425-24T"}, + {110, "Nortel Networks Wireless LAN Access Point 2221"}, + {111, "Nortel Metro Ethernet Service Unit 24-T SPF switch"}, + {112, " Nortel Metro Ethernet Service Unit 24-T LX DC switch"}, + {113, "Passport 8300 10-slot chassis"}, + {114, "Passport 8300 6-slot chassis"}, + {115, "Ethernet Routing Switch 5520-24T-PWR"}, + {116, "Ethernet Routing Switch 5520-48T-PWR"}, + {117, "Nortel Networks VPN Gateway 3050"}, + {118, "Alteon SSL 310 10/100"}, + {119, "Alteon SSL 310 10/100 Fiber"}, + {120, "Alteon SSL 310 10/100 FIPS"}, + {121, "Alteon SSL 410 10/100/1000"}, + {122, "Alteon SSL 410 10/100/1000 Fiber"}, + {123, "Alteon Application Switch 2424-SSL"}, + {124, "Ethernet Switch 325-24T"}, + {125, "Ethernet Switch 325-24G"}, + {126, "Nortel Networks Wireless LAN Access Point 2225"}, + {127, "Nortel Networks Wireless LAN SecuritySwitch 2270"}, + {128, "24-port Ethernet Switch 470-24T-PWR"}, + {129, "48-port Ethernet Switch 470-48T-PWR"}, + {130, "Ethernet Routing Switch 5530-24TFD"}, + {131, "Ethernet Switch 3510-24T"}, + {132, "Nortel Metro Ethernet Service Unit 12G AC L3 switch"}, + {133, "Nortel Metro Ethernet Service Unit 12G DC L3 switch"}, + {134, "Nortel Secure Access Switch"}, + {135, "Nortel Networks VPN Gateway 3070"}, + {136, "OPTera Metro 3500"}, + {137, "SMB BES 1010 24T"}, + {138, "SMB BES 1010 48T"}, + {139, "SMB BES 1020 24T PWR"}, + {140, "SMB BES 1020 48T PWR"}, + {141, "SMB BES 2010 24T"}, + {142, "SMB BES 2010 48T"}, + {143, "SMB BES 2020 24T PWR"}, + {144, "SMB BES 2020 48T PWR"}, + {145, "SMB BES 110 24T"}, + {146, "SMB BES 110 48T"}, + {147, "SMB BES 120 24T PWR"}, + {148, "SMB BES 120 48T PWR"}, + {149, "SMB BES 210 24T"}, + {150, "SMB BES 210 48T"}, + {151, "SMB BES 220 24T PWR"}, + {152, "SMB BES 220 48T PWR"}, + {153, "OME 6500"}, + {154, "Ethernet Routing Switch 4548GT"}, + {155, "Ethernet Routing Switch 4548GT-PWR"}, + {156, "Ethernet Routing Switch 4550T"}, + {157, "Ethernet Routing Switch 4550T-PWR"}, + {158, "Ethernet Routing Switch 4526FX"}, + {159, "Ethernet Routing Switch 2500-26T"}, + {160, "Ethernet Routing Switch 2500-26T-PWR"}, + {161, "Ethernet Routing Switch 2500-50T"}, + {162, "Ethernet Routing Switch 2500-50T-PWR"}, + {0, NULL} +}; + +/* from synro179.mib - SnpxBackplaneType */ +static const value_string ndp_backplane_val[] = +{ + {1, "Other"}, + {2, "Ethernet"}, + {3, "Ethernet and Tokenring"}, + {4, "Ethernet and FDDI"}, + {5, "Ethernet, Tokenring and FDDI"}, + {6, "Ethernet and Tokenring with redundant power"}, + {7, "Ethernet, Tokenring, FDDI with redundant power"}, + {8, "Token Ring"}, + {9, "Ethernet, Tokenring and Fast Ethernet"}, + {10, "Ethernet and Fast Ethernet"}, + {11, "Ethernet, Tokenring, Fast Ethernet with redundant power"}, + {12, "Ethernet, Fast Ethernet and Gigabit Ethernet"}, + {0, NULL} +}; + +static const value_string ndp_state_val[] = +{ + {1, "Topology Change"}, + {2, "Heartbeat"}, + {3, "New"}, + {0, NULL} +}; + + +/* Offsets in NDP Hello structure. */ +#define NDP_IP_ADDRESS 0 +#define NDP_SEGMENT_IDENTIFIER 4 +#define NDP_CHASSIS_TYPE 7 +#define NDP_BACKPLANE_TYPE 8 +#define NDP_STATE 9 +#define NDP_NUMBER_OF_LINKS 10 + +static int proto_ndp = -1; +static int hf_ndp_ip_address = -1; +static int hf_ndp_segment_identifier = -1; +static int hf_ndp_chassis_type = -1; +static int hf_ndp_backplane_type = -1; +static int hf_ndp_state = -1; +static int hf_ndp_number_of_links = -1; + +static gint ett_ndp = -1; + + +static void +dissect_ndp(tvbuff_t *tvb, packet_info *pinfo, proto_tree *tree) +{ + const char *hello_type; + proto_tree *ndp_tree = NULL; + proto_item *ti; + + col_set_str(pinfo->cinfo, COL_PROTOCOL, "NDP"); + + if (check_col(pinfo->cinfo, COL_INFO)) { + hello_type = ""; + if (pinfo->dl_dst.type == AT_ETHER) { + const guint8 *dstmac = pinfo->dl_dst.data; + + switch (dstmac[5]) { + + case 0: + hello_type = "Segment "; + break; + + case 1: + hello_type = "FlatNet "; + break; + } + } + col_add_fstr(pinfo->cinfo, COL_INFO, "%sHello", + hello_type); + } + + if (tree) { + ti = proto_tree_add_protocol_format(tree, proto_ndp, tvb, 0, 11, + "Nortel Discovery Protocol"); + + ndp_tree = proto_item_add_subtree(ti, ett_ndp); + + proto_tree_add_item(ndp_tree, hf_ndp_ip_address, tvb, + NDP_IP_ADDRESS, 4, FALSE); + + + proto_tree_add_item(ndp_tree, hf_ndp_segment_identifier, tvb, + NDP_SEGMENT_IDENTIFIER, 3, FALSE); + + + proto_tree_add_item(ndp_tree, hf_ndp_chassis_type, tvb, + NDP_CHASSIS_TYPE, 1, FALSE); + + proto_tree_add_item(ndp_tree, hf_ndp_backplane_type, tvb, + NDP_BACKPLANE_TYPE, 1, FALSE); + + + proto_tree_add_item(ndp_tree, hf_ndp_state, tvb, + NDP_STATE, 1, FALSE); + + proto_tree_add_item(ndp_tree, hf_ndp_number_of_links, tvb, + NDP_NUMBER_OF_LINKS, 1, FALSE); + } + + +} + + + +void +proto_register_ndp(void) +{ + static hf_register_info hf[] = { + { &hf_ndp_ip_address, + { "IP address", "ndp.ipaddress", FT_IPv4, BASE_NONE, NULL, 0x0, + "IP address of the Network Management Module (NMM))", HFILL }}, + + { &hf_ndp_segment_identifier, + { "Segment Identifier", "ndp.segmentident", FT_UINT24, BASE_HEX, NULL, 0x0, + "Segment id of the segment from which the agent is sending the topology message", HFILL }}, + + { &hf_ndp_chassis_type, + { "Chassis type", "ndp.chassis", FT_UINT8, BASE_DEC, + VALS(ndp_chassis_val), 0x0, + "Chassis type of the agent sending the topology message", HFILL }}, + + { &hf_ndp_backplane_type, + { "Backplane type", "ndp.backplane", FT_UINT8, BASE_DEC, + VALS(ndp_backplane_val), 0x0, + "Backplane type of the agent sending the topology message", HFILL }}, + + { &hf_ndp_state, + { "State", "ndp.state", FT_UINT8, BASE_DEC, + VALS(ndp_state_val), 0x0, + "Current state of this Network Management Module (NMM)", HFILL }}, + + { &hf_ndp_number_of_links, + { "Number of links", "ndp.numberoflinks", FT_UINT8, BASE_DEC, NULL, 0x0, + "Number of interconnect ports", HFILL }}, + }; + + static gint *ett[] = { + &ett_ndp, + }; + proto_ndp = proto_register_protocol("Nortel NDP", "NDP", "ndp"); + proto_register_field_array(proto_ndp, hf, array_length(hf)); + proto_register_subtree_array(ett, array_length(ett)); + + register_dissector("ndp", dissect_ndp, proto_ndp); +} + +void +proto_reg_handoff_ndp(void) +{ + dissector_handle_t ndp_handle; + + ndp_handle = find_dissector("ndp"); + + dissector_add("llc.nortel_pid", 0x01a1, ndp_handle); /* flatnet hello */ + dissector_add("llc.nortel_pid", 0x01a2, ndp_handle); /* Segment hello */ + /* not got round to adding this but its really old, so I'm not sure people will see it */ + /* it uses a different packet format */ + /* dissector_add("llc.nortel_pid", 0x01a3, ndp_handle); */ /* Bridge hello */ +} |