After discussion in [1] and further look at the code, it became obvios
rx_underrun events are not happening in general for any SDR (don't
exist), so let's drop that counter. Instead, add Tx Dropped Packet counters,
which were not accounted prior to this commit.
[1] https://github.com/osmocom/osmo-trx/commit/bde55afd29fc9aae10eb11f6515821afa39b772d
Change-Id: Iff1535c219a4695a511d383d7c4b06ef6eff959d
|
|
osmo-trx will validate over time that those thresholds are not reached.
If they are reached, osmo-trx will die. As a result, osmo-bts-trx will
notice and will end up notifying the BSC about it (for instance because
it will also restart its process).
For instance:
"""
ctr-error-threshold rx_drop_events 2 minute
ctr-error-threshold rx_underruns 10 second
"""
In those cases above, osmo-trx will die if rate_ctr rx_drop_events went
to a value higher than 2 per minute, or it will die to if rx_underruns
went higher than 10 per second.
Change-Id: I4bcf44dbf064e2e86dfc3b8a2ad18fea76fbd51a
|
|
Introduce a unified implementation-agnostic interface for radioDevice to
signal SDR error counters to upper layers and manage them.
This patch only implements counters for osmo-trx-lms (other devices will
show all counters unchanged during time).
Sample use through VTY:
"""
OsmoTRX> show rate-counters
osmo-trx statistics 0:
device:rx_underruns: 0 (0/s 0/m 0/h 0/d) Number of Rx underruns
device:rx_overruns: 0 (0/s 0/m 0/h 0/d) Number of Rx overruns
device:tx_underruns: 0 (0/s 0/m 0/h 0/d) Number of Tx underruns
device:rx_drop_events: 4 (0/s 2/m 3/h 0/d) Number of times Rx samples were dropped by HW
device:rx_drop_samples: 513 (0/s 196/m 425/h 0/d) Number of Rx samples dropped by HW
"""
Change-Id: I78b158141697e5714d04db8b9ccc96f31f34f439
|