aboutsummaryrefslogtreecommitdiffstats
path: root/tests
diff options
context:
space:
mode:
authorVadim Yanitskiy <axilirator@gmail.com>2019-11-08 05:37:18 +0700
committerVadim Yanitskiy <axilirator@gmail.com>2019-11-08 06:20:55 +0700
commitfd734de4d176420199d8badb9262329dc0603780 (patch)
treec80a35a0a04b7046da26bc13d83b013d53c2a1e9 /tests
parent87b6e7dbedff01c5dbc5883198ca57d25f19eb5b (diff)
GprsMs::update_cs_ul(): clarify the meaning of old_link_qual
Diffstat (limited to 'tests')
-rw-r--r--tests/tbf/TbfTest.err20
1 files changed, 10 insertions, 10 deletions
diff --git a/tests/tbf/TbfTest.err b/tests/tbf/TbfTest.err
index 6e638aff..8ec3e80d 100644
--- a/tests/tbf/TbfTest.err
+++ b/tests/tbf/TbfTest.err
@@ -1470,7 +1470,7 @@ TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) TX: START Immediate Assignment Upli
- TRX=0 (0) TS=7 TA=7 TSC=0 TFI=0 USF=0
Got CS-1 RLC block: R=0, SI=0, TFI=0, CPS=0, RSB=0, rc=184
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) UL DATA TFI=0 received (V(Q)=0 .. V(R)=0)
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) restarting timer T3169 [acked (data)] with 5 sec. 0 microsec, cur_fn=0
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) Got CS-1 RLC data block: CV=0, BSN=0, SPB=0, PI=0, E=1, TI=1, bitoffs=24
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) BSN 0 storing in window (0..63)
@@ -1827,7 +1827,7 @@ Modifying MS object, UL TLLI: 0x00000000 -> 0xf1223344, not yet confirmed
Modifying MS object, TLLI = 0xf1223344, TA 220 -> 7
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) change control TS 7 -> 7 until assinment is complete.
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes UL ASS state from GPRS_RLCMAC_UL_ASS_NONE to GPRS_RLCMAC_UL_ASS_SEND_ASS
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) start Packet Uplink Assignment (PACCH)
+++++++++++++++++++++++++ TX : Packet Uplink Assignment +++++++++++++++++++++++++
------------------------- TX : Packet Uplink Assignment -------------------------
@@ -1842,7 +1842,7 @@ TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes UL ASS state from GPRS_RL
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes state from ASSIGN to FLOW
Got CS-1 RLC block: R=0, SI=0, TFI=0, CPS=0, RSB=0, rc=184
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) UL DATA TFI=0 received (V(Q)=0 .. V(R)=0)
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-2 -> CS-3
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-2 -> CS-3
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) restarting timer T3169 [acked (data)] with 5 sec. 0 microsec, cur_fn=0
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) Got CS-1 RLC data block: CV=15, BSN=0, SPB=0, PI=0, E=1, TI=0, bitoffs=24
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) BSN 0 storing in window (0..63)
@@ -1920,7 +1920,7 @@ TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=NULL) changes state from NULL to ASSIGN
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) starting timer T3169 [allocation (UL-TBF)] with 5 sec. 0 microsec, cur_fn=0
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) change control TS 7 -> 7 until assinment is complete.
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes UL ASS state from GPRS_RLCMAC_UL_ASS_NONE to GPRS_RLCMAC_UL_ASS_SEND_ASS
-MS (IMSI 0011223344): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-3 -> CS-4
+MS (IMSI 0011223344): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-3 -> CS-4
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) start Packet Uplink Assignment (PACCH)
+++++++++++++++++++++++++ TX : Packet Uplink Assignment +++++++++++++++++++++++++
------------------------- TX : Packet Uplink Assignment -------------------------
@@ -1999,7 +1999,7 @@ Modifying MS object, UL TLLI: 0x00000000 -> 0xf1223344, not yet confirmed
Modifying MS object, TLLI = 0xf1223344, TA 220 -> 7
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) change control TS 7 -> 7 until assinment is complete.
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes UL ASS state from GPRS_RLCMAC_UL_ASS_NONE to GPRS_RLCMAC_UL_ASS_SEND_ASS
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) start Packet Uplink Assignment (PACCH)
+++++++++++++++++++++++++ TX : Packet Uplink Assignment +++++++++++++++++++++++++
------------------------- TX : Packet Uplink Assignment -------------------------
@@ -2014,7 +2014,7 @@ TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes UL ASS state from GPRS_RL
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes state from ASSIGN to FLOW
Got CS-1 RLC block: R=0, SI=0, TFI=0, CPS=0, RSB=0, rc=184
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) UL DATA TFI=0 received (V(Q)=0 .. V(R)=0)
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-2 -> CS-3
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-2 -> CS-3
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) restarting timer T3169 [acked (data)] with 5 sec. 0 microsec, cur_fn=0
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) Got CS-1 RLC data block: CV=15, BSN=0, SPB=0, PI=0, E=1, TI=0, bitoffs=24
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) BSN 0 storing in window (0..63)
@@ -2085,7 +2085,7 @@ TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) TX: START Immediate Assignment Upli
- TRX=0 (0) TS=7 TA=7 TSC=0 TFI=0 USF=0
Got CS-1 RLC block: R=0, SI=0, TFI=0, CPS=0, RSB=0, rc=184
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) UL DATA TFI=0 received (V(Q)=0 .. V(R)=0)
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) restarting timer T3169 [acked (data)] with 5 sec. 0 microsec, cur_fn=0
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) Got CS-1 RLC data block: CV=0, BSN=0, SPB=0, PI=0, E=1, TI=1, bitoffs=24
TBF(TFI=0 TLLI=0x00000000 DIR=UL STATE=FLOW) BSN 0 storing in window (0..63)
@@ -2150,7 +2150,7 @@ Modifying MS object, UL TLLI: 0x00000000 -> 0xf1223344, not yet confirmed
Modifying MS object, TLLI = 0xf1223344, TA 220 -> 7
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) change control TS 7 -> 7 until assinment is complete.
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes UL ASS state from GPRS_RLCMAC_UL_ASS_NONE to GPRS_RLCMAC_UL_ASS_SEND_ASS
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-1 -> CS-2
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) start Packet Uplink Assignment (PACCH)
+++++++++++++++++++++++++ TX : Packet Uplink Assignment +++++++++++++++++++++++++
------------------------- TX : Packet Uplink Assignment -------------------------
@@ -2165,7 +2165,7 @@ TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes UL ASS state from GPRS_RL
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=ASSIGN) changes state from ASSIGN to FLOW
Got CS-1 RLC block: R=0, SI=0, TFI=0, CPS=0, RSB=0, rc=184
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) UL DATA TFI=0 received (V(Q)=0 .. V(R)=0)
-MS (IMSI ): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-2 -> CS-3
+MS (IMSI ): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-2 -> CS-3
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) restarting timer T3169 [acked (data)] with 5 sec. 0 microsec, cur_fn=0
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) Got CS-1 RLC data block: CV=15, BSN=0, SPB=0, PI=0, E=1, TI=0, bitoffs=24
TBF(TFI=0 TLLI=0xf1223344 DIR=UL STATE=FLOW) BSN 0 storing in window (0..63)
@@ -2829,7 +2829,7 @@ TBF(TFI=0 TLLI=0xf1223344 DIR=DL STATE=WAIT RELEASE) changes DL ASS state from G
TBF(TFI=1 TLLI=0xf1223344 DIR=DL STATE=NULL) changes state from NULL to ASSIGN
TBF(TFI=1 TLLI=0xf1223344 DIR=DL STATE=ASSIGN) set ass. type PACCH [prev CCCH:0, PACCH:0]
TBF(TFI=1 TLLI=0xf1223344 DIR=DL STATE=ASSIGN) starting timer T0 [assignment (PACCH)] with 2 sec. 0 microsec, cur_fn=0
-MS (IMSI 0011223344): Link quality 12dB (12dB) left window [0, 0], modifying uplink CS level: CS-3 -> CS-4
+MS (IMSI 0011223344): Link quality 12dB (old 12dB) left window [0, 0], modifying uplink CS level: CS-3 -> CS-4
Received RTS for PDCH: TRX=0 TS=7 FN=2654400 block_nr=2 scheduling USF=0 for required uplink resource of UL TFI=0
TBF(TFI=1 TLLI=0xf1223344 DIR=DL STATE=ASSIGN) start Packet Downlink Assignment (PACCH)
+++++++++++++++++++++++++ TX : Packet Downlink Assignment +++++++++++++++++++++++++