diff options
Diffstat (limited to 'src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c')
-rw-r--r-- | src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c | 279 |
1 files changed, 0 insertions, 279 deletions
diff --git a/src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c b/src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c deleted file mode 100644 index 9a77a95a..00000000 --- a/src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c +++ /dev/null @@ -1,279 +0,0 @@ -/* (C) 2014 by sysmocom - s.f.m.c. GmbH - * - * All Rights Reserved - * - * Author: Alvaro Neira Ayuso <anayuso@sysmocom.de> - * - * This program is free software; you can redistribute it and/or modify - * it under the terms of the GNU Affero General Public License as published by - * the Free Software Foundation; either version 3 of the License, or - * (at your option) any later version. - * - * This program is distributed in the hope that it will be useful, - * but WITHOUT ANY WARRANTY; without even the implied warranty of - * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the - * GNU General Public License for more details. - * - * You should have received a copy of the GNU Affero General Public License - * along with this program. If not, see <http://www.gnu.org/licenses/>. - * - */ - -#include <stdlib.h> -#include <unistd.h> -#include <errno.h> -#include <stdint.h> -#include <ctype.h> -#include <string.h> -#include <sys/socket.h> -#include <netinet/in.h> -#include <arpa/inet.h> - -#include <osmocom/vty/vty.h> -#include <osmocom/vty/command.h> -#include <osmocom/vty/misc.h> - -#include <osmo-bts/logging.h> - -#include "sysmobts_misc.h" -#include "sysmobts_mgr.h" - -static struct sbts2050_config_info *mgr_cfg; - -enum node_type mgr_vty_go_parent(struct vty *vty) -{ - switch (vty->node) { - case MGR_NODE: - vty->node = CONFIG_NODE; - break; - default: - vty->node = CONFIG_NODE; - } - return vty->node; -} - -int mgr_vty_is_config_node(struct vty *vty, int node) -{ - switch (node) { - case MGR_NODE: - return 1; - default: - return 0; - } -} - -#define MGR_STR "Configure sysmobts-mgr\n" -#define MGR_TEMP_WARN_STR "Configure the temperature warning limits\n" -#define MGR_TEMP_SEVERE_STR "Configure the temperature severe limits\n" - -static struct cmd_node mgr_node = { - MGR_NODE, - "%s(config-mgr)# ", - 1, -}; - -DEFUN(cfg_mgr, cfg_mgr_cmd, - "config-mgr", - MGR_STR) -{ - vty->node = MGR_NODE; - return CMD_SUCCESS; -} - -DEFUN(show_mgr, show_mgr_cmd, "show mgr", - SHOW_STR "Display information about the mgr") -{ - vty_out(vty, " temperature-warning board Min:%d Max:%d%s", - mgr_cfg->temp_min_board_warn_limit, - mgr_cfg->temp_max_board_warn_limit, - VTY_NEWLINE); - - vty_out(vty, " temperature-severe board Min:%d Max:%d%s", - mgr_cfg->temp_min_board_severe_limit, - mgr_cfg->temp_max_board_severe_limit, - VTY_NEWLINE); - - vty_out(vty, " temperature-warning pa Min:%d Max:%d%s", - mgr_cfg->temp_min_pa_warn_limit, - mgr_cfg->temp_max_pa_warn_limit, - VTY_NEWLINE); - - vty_out(vty, " temperature-severe pa Min:%d Max:%d%s", - mgr_cfg->temp_min_pa_severe_limit, - mgr_cfg->temp_max_pa_severe_limit, - VTY_NEWLINE); - - vty_out(vty, " power-action Master:%s Slave:%s PA:%s%s", - mgr_cfg->master_power_act ? "on" : "off", - mgr_cfg->slave_power_act ? "on" : "off", - mgr_cfg->pa_power_act ? "on" : "off", - VTY_NEWLINE); - - vty_out(vty, " power-reduce-transmitter %d%s", - mgr_cfg->reduce_max_power, - VTY_NEWLINE); - return CMD_SUCCESS; -} - -static int config_write_mgr(struct vty *vty) -{ - vty_out(vty, "config-mgr%s", VTY_NEWLINE); - - vty_out(vty, " temperature-warning board %d %d%s", - mgr_cfg->temp_min_board_warn_limit, - mgr_cfg->temp_max_board_warn_limit, - VTY_NEWLINE); - - vty_out(vty, " temperature-severe board %d %d%s", - mgr_cfg->temp_min_board_severe_limit, - mgr_cfg->temp_max_board_severe_limit, - VTY_NEWLINE); - - vty_out(vty, " temperature-warning pa %d %d%s", - mgr_cfg->temp_min_pa_warn_limit, - mgr_cfg->temp_max_pa_warn_limit, - VTY_NEWLINE); - - vty_out(vty, " temperature-severe pa %d %d%s", - mgr_cfg->temp_min_pa_severe_limit, - mgr_cfg->temp_max_pa_severe_limit, - VTY_NEWLINE); - - vty_out(vty, " power-action %s %s %s%s", - mgr_cfg->master_power_act ? "on" : "off", - mgr_cfg->slave_power_act ? "on" : "off", - mgr_cfg->pa_power_act ? "on" : "off", - VTY_NEWLINE); - - vty_out(vty, " power-reduce-transmitter %d%s", - mgr_cfg->reduce_max_power, - VTY_NEWLINE); - - return CMD_SUCCESS; -} - -DEFUN(cfg_mgr_board_temp_warn, cfg_mgr_board_temp_warn_cmd, - "temperature-warning board <-255-255> <-255-255>", - MGR_TEMP_WARN_STR - "Set warning temperature limits on the Board\n" - "Warning temperature low limit on the Board\n" - "Warning temperature high limit on the Board\n") -{ - mgr_cfg->temp_min_board_warn_limit = atoi(argv[0]); - mgr_cfg->temp_max_board_warn_limit = atoi(argv[1]); - - return CMD_SUCCESS; -} - -DEFUN(cfg_mgr_board_temp_sever, cfg_mgr_board_temp_sever_cmd, - "temperature-severe board <-255-255> <-255-255>", - MGR_TEMP_SEVERE_STR - "Set severe temperature limits on the Board\n" - "Severe temperature low limit on the Board\n" - "Severe Temperature high limit on the Board\n") -{ - mgr_cfg->temp_min_board_severe_limit = atoi(argv[0]); - mgr_cfg->temp_max_board_severe_limit = atoi(argv[1]); - - return CMD_SUCCESS; -} - -DEFUN(cfg_mgr_pa_temp_warn, cfg_mgr_pa_temp_warn_cmd, - "temperature-warning pa <-255-255> <-255-255>", - MGR_TEMP_WARN_STR - "Set warning temperature limits on the PA\n" - "Warning temperature low limit on the PA\n" - "Warning temperature high limit on the PA\n") -{ - mgr_cfg->temp_min_pa_warn_limit = atoi(argv[0]); - mgr_cfg->temp_max_pa_warn_limit = atoi(argv[1]); - - return CMD_SUCCESS; -} - -DEFUN(cfg_mgr_pa_temp_sever, cfg_mgr_pa_temp_sever_cmd, - "temperature-severe pa <-255-255> <-255-255>", - MGR_TEMP_SEVERE_STR - "Set severe temperature limits on the Board\n" - "Severe temperature low limit on the PA\n" - "Severe temperature high limit on the PA\n") -{ - mgr_cfg->temp_min_pa_severe_limit = atoi(argv[0]); - mgr_cfg->temp_max_pa_severe_limit = atoi(argv[1]); - - return CMD_SUCCESS; -} - -DEFUN(cfg_mgr_pwr_action, cfg_mgr_pwr_action_cmd, - "power-action (on|off) (on|off) (on|off)", - "Configure which devices we want to turn on/off in several situation\n" - "Turn on the Master\n" - "Turn off the Master\n" - "Turn on the Slave\n" - "Turn off the Slave\n" - "Turn on the PA\n" - "Turn off the PA\n") -{ - if (strcmp(argv[0], "on") == 0) - mgr_cfg->master_power_act = 1; - else if (strcmp(argv[0], "off") == 0) - mgr_cfg->master_power_act = 0; - - if (strcmp(argv[1], "on") == 0) - mgr_cfg->slave_power_act = 1; - else if (strcmp(argv[1], "off") == 0) - mgr_cfg->slave_power_act = 0; - - if (strcmp(argv[2], "on") == 0) - mgr_cfg->pa_power_act = 1; - else if (strcmp(argv[2], "off") == 0) - mgr_cfg->pa_power_act = 0; - - return CMD_SUCCESS; -} - -DEFUN(cfg_mgr_pa_baud_action, cfg_mgr_pa_baud_action_cmd, - "power-reduce-transmitter <0-255>", - "Configure the power that we want to reduce in warning situation\n" - "Power baud transmition that we want to reduce in the PA\n") -{ - mgr_cfg->reduce_max_power = atoi(argv[0]); - - return CMD_SUCCESS; -} - -int sysmobts_mgr_vty_init(void) - -{ - install_element_ve(&show_mgr_cmd); - - install_node(&mgr_node, config_write_mgr); - install_element(CONFIG_NODE, &cfg_mgr_cmd); - vty_install_default(MGR_NODE); - - install_element(MGR_NODE, &cfg_mgr_board_temp_warn_cmd); - install_element(MGR_NODE, &cfg_mgr_board_temp_sever_cmd); - install_element(MGR_NODE, &cfg_mgr_pa_temp_warn_cmd); - install_element(MGR_NODE, &cfg_mgr_pa_temp_sever_cmd); - install_element(MGR_NODE, &cfg_mgr_pwr_action_cmd); - install_element(MGR_NODE, &cfg_mgr_pa_baud_action_cmd); - - return 0; -} - -int sysmobts_mgr_parse_config(const char *config_file, - struct sbts2050_config_info *cfg) -{ - int rc; - - mgr_cfg = cfg; - - rc = vty_read_config_file(config_file, NULL); - if (rc < 0) { - fprintf(stderr, "Failed to parse the config file: '%s'\n", - config_file); - return rc; - } - - return 0; -} |