blob: 22e2a0668c983d42d6514354e01f90f7afe4e3af (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
|
OsmoBSC> enable
OsmoBSC# list
...
bts <0-255> trx <0-255> timeslot <0-7> sub-slot <0-7> modify (vamos|non-vamos) [tsc] [<1-4>] [<0-7>]
...
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 ?
activate Manual Channel Activation (e.g. for BER test)
activate-vamos Manual Channel Activation, in VAMOS mode
deactivate Manual Channel Deactivation (e.g. for BER test)
modify Manually send Channel Mode Modify (for debugging)
mdcx Modify RTP Connection
reassign-to Trigger Assignment to an unused lchan on the same cell
handover Manually trigger handover (for debugging)
assignment Manually trigger assignment (for debugging)
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 modify ?
vamos Enable VAMOS channel mode
non-vamos Disable VAMOS channel mode
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 modify vamos ?
[tsc] Provide specific TSC Set and Training Sequence Code
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 modify vamos tsc ?
[<1-4>] TSC Set
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 modify vamos tsc 1 ?
[<0-7>] Training Sequence Code
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 modify vamos tsc 1 0 ?
<cr>
OsmoBSC# list
...
bts <0-255> trx <0-255> timeslot <0-7> (sub-slot|vamos-sub-slot) <0-7> (activate|activate-vamos|deactivate) (hr|fr|efr|amr|sig) [<0-7>]
...
OsmoBSC# bts?
bts BTS Specific Commands
OsmoBSC# bts ?
<0-255> BTS Number
OsmoBSC# bts 0 ?
resend-system-information Re-generate + re-send BCCH SYSTEM INFORMATION
resend-power-control-defaults Re-generate + re-send default MS/BS Power control parameters
c0-power-reduction BCCH carrier power reduction operation
trx TRX for manual command
oml Manipulate the OML managed objects
om2000 Manipulate the OM2000 managed objects
OsmoBSC# bts 0 c0-power-reduction ?
<0-6> Power reduction value (in dB, even numbers only)
OsmoBSC# bts 0 trx ?
<0-255> TRX Number
OsmoBSC# bts 0 trx 0 ?
timeslot Timeslot for manual command
OsmoBSC# bts 0 trx 0 timeslot ?
<0-7> Timeslot Number
OsmoBSC# bts 0 trx 0 timeslot 0 ?
pdch Packet Data Channel
sub-slot Primary sub-slot
vamos-sub-slot VAMOS secondary shadow subslot, range <0-1>, only valid for TCH type timeslots
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot ?
<0-7> Sub-slot Number
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 ?
activate Manual Channel Activation (e.g. for BER test)
activate-vamos Manual Channel Activation, in VAMOS mode
deactivate Manual Channel Deactivation (e.g. for BER test)
modify Manually send Channel Mode Modify (for debugging)
mdcx Modify RTP Connection
reassign-to Trigger Assignment to an unused lchan on the same cell
handover Manually trigger handover (for debugging)
assignment Manually trigger assignment (for debugging)
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 activate ?
hr Half-Rate v1
fr Full-Rate
efr Enhanced Full Rate
amr Adaptive Multi-Rate
sig Signalling
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 activate fr ?
[<0-7>] AMR Mode
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 activate fr 0 ?
<cr>
OsmoBSC# list
...
bts <0-255> trx <0-255> timeslot <0-7> (sub-slot|vamos-sub-slot) <0-7> reassign-to trx <0-255> timeslot <0-7> (sub-slot|vamos-sub-slot) <0-7> [tsc] [<1-4>] [<0-7>]
...
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to ?
trx Target TRX
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx ?
<0-255> TRX nr
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 ?
timeslot Target timeslot
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 timeslot ?
<0-7> timeslot nr
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 timeslot 0 ?
sub-slot Primary sub-slot
vamos-sub-slot VAMOS secondary shadow subslot, range <0-1>, only valid for TCH type timeslots
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 timeslot 0 vamos-sub-slot ?
<0-7> Sub-slot Number
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 timeslot 0 vamos-sub-slot 0 ?
[tsc] Provide specific TSC Set and Training Sequence Code
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 timeslot 0 vamos-sub-slot 0 tsc ?
[<1-4>] TSC Set
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 timeslot 0 vamos-sub-slot 0 tsc 1 ?
[<0-7>] Training Sequence Code
OsmoBSC# bts 0 trx 0 timeslot 0 sub-slot 0 reassign-to trx 0 timeslot 0 vamos-sub-slot 0 tsc 1 0 ?
<cr>
OsmoBSC# configure terminal
OsmoBSC(config)# network
OsmoBSC(config-net)# list
...
meas-feed destination ADDR <0-65535>
meas-feed scenario NAME
...
OsmoBSC(config-net)# meas-feed destination 127.0.0.23 4223
OsmoBSC(config-net)# meas-feed scenario foo23
OsmoBSC(config-net)# show running-config
...
network
...
meas-feed destination 127.0.0.23 4223
meas-feed scenario foo23
...
|