# No Hysteresis and minimum RX level # If current cell's RX level is below mimium level, handover must be # performed, no matter of the hysteresis. First do not perform # handover to better neighbor cell, because the hysteresis is not # met. Second do not perform handover because better neighbor cell is # below minimum RX level. Third perform handover because current cell # is below minimum RX level, even if the better neighbor cell (minimum # RX level reached) does not meet the hysteresis. create-n-bts 2 set-ts-use trx 0 0 states * TCH/F - - - - - - meas-rep lchan 0 0 1 0 rxlev 10 rxqual 0 ta 0 neighbors 11 expect-no-chan meas-rep lchan 0 0 1 0 rxlev 8 rxqual 0 ta 0 neighbors 9 expect-no-chan meas-rep lchan 0 0 1 0 rxlev 9 rxqual 0 ta 0 neighbors 10 expect-ho from lchan 0 0 1 0 to lchan 1 0 1 0 expect-ts-use trx 0 0 states * - - - - - - - expect-ts-use trx 1 0 states * TCH/F - - - - - -