Age | Commit message (Collapse) | Author | Files | Lines |
|
Default value is the current default of 5s for all timers that are not
specified. It should be changed to what the spec says instead.
Related: SYS#4897
Change-Id: I637fcdde93c11158de46157d494c060bb36bdcfb
|
|
Change-Id: I491d319f2829902a8c449db515f928cf7e480482
|
|
The VTY command parser would not allow values other than 0 or 1.
Change-Id: Ic29fac12414f1821702759a9f5260e941c9868b5
|
|
Change-Id: I344ea61df8cc910d9b524c9b2f0e03721eefe56c
|
|
Change-Id: Ib21c30041508a9ec9afda56bda95bddf4d665bc8
|
|
This logging category has been removed in [1], what caused test
case execution failures on our Jenkins (since build #930). The
problem is that configuration files may still contain this
category in 'logging' section (see [2], [3], [4]), and
osmo-bsc would refuse to start because of that.
[1] Id965295dfe04f8bd5ce831db70c86f67b8dc290b
[2] Ie2afacfc15589c26238214cddc00baaf80e993c1
[3] I266d6f6ed54d1457b1ca63b87fc1c29f6dd40caf
[4] If02272c08ba2df37d1295d09c104d11f96abbe1e
Change-Id: I111362d19aba325889bada5a46eea62343c30033
|
|
This dates back to a time where osmo-bsc_nat was in the same repository,
which is a long time ago.
Change-Id: Id965295dfe04f8bd5ce831db70c86f67b8dc290b
|
|
Change-Id: I8eddc47353d6afd756865321a9e97f6cee4ce2d7
|
|
Link to the osmo-gsm-manuals/common/cs7-config.adoc chapter to fully explain
the 'cs7' client configuration.
Related: OS#2767
Depends: Ia2508d4c7b0fef9cdc57e7e122799a480e340bf7 (osmo-gsm-manuals)
Change-Id: I5b4973901f02046322b852fd9862517982d21bd9
|
|
Change-Id: I8d807ffc4571f2954e3d1083da673dc1235e7687
|
|
If, as before this patch we call initCDKScreen() before
attempting to bind the socket, then the socket bind fails,
we exit and the terminal needs a reset.
Attempt to open the socket before initCDKScreen()
so we don't end up with a messed up terminal if the socket
call fails.
Change-Id: Ia5148d9ef386df314bc2837b3cb672150250bd2a
|
|
The measurement tools use libosmocore socket functions that will
use logging if the socket cannot be opened, but the tools did
not initialise logging, resulting in
Assert failed osmo_log_info logging.c:235
backtrace() returned 9 addresses
[.....]
Initialise logging so that we get a nicer and more informative
message, such as:
unable to bind socket:(null):8888: Address already in use
no suitable addr found for: (null):8888
Change-Id: Ib3b3558723682defcee22e7ea2d8bf5c2cff1278
|
|
Change-Id: I27bcde8d36dcf8daa9d24b4b581c9526b73cb35e
|
|
Change-Id: I00a183078679db50567286a78c9e4f9afa3466c6
|
|
Save OML failure reports from each BTS. Add a VTY command to display them
conveniently and optionally clear the list.
OsmoBSC> show bts 0 fail-rep
[2020-03-23 14:51:22] Type=processing failure, Severity=minor failure, Probable cause=Manufacturer specific values: Software warning, Additional text=test message sent from VTY
[2020-03-23 14:51:19] Type=processing failure, Severity=minor failure, Probable cause=Manufacturer specific values: Software warning, Additional text=test message sent from VTY
Related: OS#1605
Change-Id: I18aa17a721cd5eb1c98926dc2367229c0a50bc78
|
|
Separate raw input parsing from handling the failure report. A follow-up
patch will use the new parsing function to print saved failure reports
to the VTY.
While at it, put struct tlv_parsed inside struct nm_fail_rep_signal_data
instead of a pointer, so we don't need an additional alloc. Also add
error handling to the abis_nm_tlv_parse() call.
Related: OS#1605
Change-Id: Ia51004faf620aa4d40435d58c70d758c9d0054d8
|
|
Use the extra bts pointer instead of mb->trx->bts, which does not point
to an allocated bts.
Related: OS#1605
Change-Id: Ie61512f5690763fa380bdf0e7fb4763dbda019d2
|
|
Related: OS#2767
Change-Id: Ideb137f19d19144d35b05eb036098045bbb18d64
|
|
Refuse to start with mutually exclusive codec settings, unless
allow-unusable-timeslots is set in the network section of the config.
The checks were already implemented and fill the error log if the config
is invalid.
Related: OS#3739
Change-Id: I3ccfc3b0a8641400cb97a23b24d7ed92d2ad25cd
|
|
All timeslots are configured for full rate, so the codec list must also
have a full rate codec. Fix this error on startup:
"Configuration contains mutually exclusive codec settings -- check configuration!"
All other example configs don't have mutually exclusive codec settings.
Related: OS#3739
Change-Id: Iddac13c7d644ed57b6d9e6a57d23d88c01bd8b8e
|
|
Fail parsing osmo-bsc.cfg if the AMR modes are not in order or not
unique.
Related: OS#4199
Change-Id: Ic2f3690396fb0425f6b358e1e21a8b8b56eb3ae0
|
|
Do not use 0 as default, as it is reserved for signalling.
Related: OS#4408
Change-Id: I499272f16aadd89f3bdb5d749e3e4f9e07056c15
|
|
Add VTY_TEST variable, just like in osmo-hlr Change-Id
I4ad7ddb31b2bfb668b3540cfef658417dd442375.
Change-Id: Ieb08ae57bd8bb68c9a8593b3e1175eae9064ac57
|
|
Also take the chance to simplify related code and print erroneous IE
data.
Change-Id: I27ee9c6112f96d6839b8b6141888ac8fe377db65
|
|
OM2000 is not only used for the venerable RBS2000 family, but also
for the more modern RBS6000 family, specifically the DUG 20 GSM
baseband unit.
In RBS6000, there are some protocol extensions which are not yet fully
understood. However, we are understanding some bits around the MCTR
(multi carrier transceiver?), a new MO that appears to be present for
every physical RUS (Radio Unit) attached to the DUG 20.
Let's add what we have learned so far.
Thanks to Sylvain Munaut for his help with this.
Change-Id: Ib868358eca12b94c4fcca58e94ec8ab1a4edfda2
|
|
Calling osmo_tdef_vty_write() twice: with and without the 'timer '
prefix definitely looks like a bug. After setting any timer to a
custom (non-default) value, config_write_net() would generate an
incorrect configuration file:
$ osmo-bsc -c /tmp/osmo-bsc.cfg
There is no such command.
Error occurred during reading the below line:
T10 10
Change-Id: I5cc893fb2077bb21f1f661e30a7ab2af1b9bd561
|
|
The loglevels of DNM, DFILTER and DPCU are set to low, lets set them all
to NOTICE
Change-Id: I03a5426b341e9908ffc89240f97d6d3ea791b4a8
Related: OS#2577
|
|
Let's not just pass around the raw msgb, but also all other metadata,
such as the decoded parts of the TS 12.21 message.
As there's no current consumer of that signal, this creates no
compatibility issues.
Change-Id: I5d4d9d422b4e23348ffbe69c6e87a31d5574f90d
|
|
Change-Id: I21556570e35d662bb902d5c1afc911b82d5eb1e6
|
|
Make build and external tests work with python3, so we can drop
the python2 dependency.
This should be merged shortly after osmo-python-tests was migrated to
python3, and the jenkins build slaves were (automatically) updated to
have the new osmo-python-tests installed.
Related: OS#2819
Depends: osmo-python-tests I3ffc3519bf6c22536a49dad7a966188ddad351a7
Change-Id: I438ca0c4b8e7957d0f347a5b2f5c4cb93f9325e6
|
|
gsm_04_80_utils.c: In function ‘bsc_send_ussd_release_complete’:
gsm_04_80_utils.c:37:9: warning: ‘gsm0480_create_ussd_release_complete’ is deprecated: Use gsm0480_create_release_complete() instead. [-Wdeprecated-declarations]
37 | struct msgb *msg = gsm0480_create_ussd_release_complete();
| ^~~~
CC gsm_data.o
In file included from gsm_04_80_utils.c:22:
/usr/local/include/osmocom/gsm/gsm0480.h:120:14: note: declared here
120 | struct msgb *gsm0480_create_ussd_release_complete(void)
| ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
The commit is not changing the existing logic/assumption: TID 0 should
not be in use by anything else at the point the USSD is generated.
Change-Id: I739158dec62cd5f0c2080fbb426af9c024baef87
|
|
Replace python 2 code using pychart to draw a graph in
osmux-reference.adoc with the generated svg file. The upstream of
pychart is dead, there is no python 3 version, and python 2 is EOL at
the end of 2019.
This is the only time we ever made use of pychart in osmo-gsm-manuals,
so with this change, we can just drop the dependency.
I've generated the chart by saving the python code in chart.py, then:
$ ./chart.py --format=svg --font-size=3 > chart.svg
Related: OS#2819, OS#4193
Depends: osmo-ci I754b133d77743582bd84c33c74ecc9eb9ca4c0ef
Change-Id: I36b721f895caee9766528e14d854b6aa2a2fac85
|
|
Change-Id: I3b8781e220326387f1c437c39aff8661326f1e0a
|
|
After sending of NM_MT_IPACC_RSL_CONNECT message, we start a timer,
and stop it on receipt of NM_MT_IPACC_RSL_CONNECT_{ACK,NACK}. When
running a multi-trx setup, one can see the following warnings:
DRSL NOTICE abis_nm.c:2852 (bts=0,trx=1) RSL connection request timed out
DRSL NOTICE abis_nm.c:2852 (bts=0,trx=2) RSL connection request timed out
even despite NM_MT_IPACC_RSL_CONNECT is actually being acknowledged.
The problem is in abis_nm_rx_ipacc(): we cannot just use sign_link->trx,
because the message itself was received over the OML link, so this
pointer always gives us C0/TRX0. Instead, we must find a TRX by its
number from the FOH header using gsm_bts_trx_by_nr().
Change-Id: Ib4b9a198da11c88a51cfa78ffb7e7235a6365ef4
|
|
This way we can avoid the runtime overhead of checking whether or not
it is initialized over and over again. It also brings this code more
in line with other users of osmo_fsm_register().
Change-Id: I3c7220491cf6ffb1361e7259c0344df64a013a0a
|
|
Change-Id: I787c4bd4b30a6620a987efed4fd8b46e14a7ea64
|
|
Change-Id: I0297352e3cba5f01a971dc5924f0fcc67d1e6b32
|
|
Change-Id: I77e8ace007a3d6b9c40d3e158d1cdb7576aab77b
|
|
Since osmo-bsc uses the MGCP client FSMs, it is required to enable this new
feature to guarantee safe operation. The issue is described in detail in commit
logs linked below.
Depends: Ief4dba9ea587c9b4aea69993e965fbb20fb80e78 (libosmocore),
I0adc13a1a998e953b6c850efa2761350dd07e03a (libosmocore)
Related: I7df2e9202b04e7ca7366bb0a8ec53cf3bb14faf3 (osmo-mgw)
Change-Id: Ib7fce7b7d54dfb87af97544796680919e5929a50
|
|
Lots of times, the MS power class is unknown until after the first
channel has been activated, at which point the MS power class is
received in messages such as LU update or CM Service Requet.
Since the MS Power level is sent upon CHAN ACT, the only way to
communicate the change of maximum MS Power (based on MS power class)
after CHAN ACT is to send a MS Power Control msg. Let's do that.
Related: OS#4244
Change-Id: I3d6b75578e5cb9b2ad474a0ad01362d846ebe135
|
|
Change-Id: I60b20d617bd8710a95977e41ae32a431af4402a9
|
|
Change-Id: Ic72753d821c3ab72cda79be71aed1704beefe983
|
|
Change-Id: I55f478c753c38baa576abc6ba53c4f6c9cbe61c0
|
|
Related: OS#4244
Change-Id: I6bff440b7797e710bca5af94fae546e5d55e6972
|
|
Fix typos and common misspellings in code comments and in the manual.
Change-Id: I46fc9d424620c77ae9ccf78b58081bd303386d7c
|
|
As can be seen from include/osmocom/bsc/gsm_data.h:
- pchan_from_config - channel configuration from the VTY/config
(can be changed from the VTY at runtime, should not affect
the existing RSL/OML connections);
- pchan_on_init - channel configuration after the OML link is
established (pchan_from_config is copied here);
- pchan_is - the *actual* channel configuration currently active.
Since we call bootstrap_bts() during the initialization, even before
establishing any OML/RSL connections, neither pchan_on_init nor
pchan_is can be used. Let's use pchan_from_config instead.
This change fixes the problem discovered by @mqng2 and reported
together with https://gerrit.osmocom.org/c/osmo-bsc/+/15909:
CCCH_CONF in System Information Type 3 does not reflect the
actual channel configuration, and always indicates a single
CCCH combined with SDCCH. This also misleads the lchan
allocation algorithm during the MO connection establishment.
Change-Id: I8f9d7aa27f24b55732a4de933bc834ed930806fd
|
|
Do not count the number of additional CCCHs if TS0 is using combined
channel configuration (CCCH+SDCCH4), because they are only allowed
if TS0 is not combined with SDCCH.
Get rid of the 'switch' statement using the following formula:
CCCH_CONFIG = (N << 1)
where N is the number of additional CCCHs.
Change-Id: I1430500999389e9b30e55ea89a8a5ea5071f7957
|
|
As per 3GPP TS 45.002, section 3.3.2.3, and table 3 of clause 7,
the following limitations apply mapping of CCCH/BCCH channels:
- TS0/C0 shall be configured as CCCH/BCCH (optionally combined);
- combined CCCH (CCCH+SDCCH4) can only be used on TS0;
- additional CCCHs can be on TS2, TS4, and TS6;
- additional CCCHs are not allowed if TS0 is combined.
Let's make sure that OsmoBSC is properly configured before starring.
Change-Id: I758ef80f7884ba35cdf59d671ee30222ffb9d68b
|
|
Change-Id: I45c93a737ad82a2525f941e89cd19d4cedbf6f02
|
|
Change-Id: I189d34b6db78de749e1901733d0df35411e0d583
|