aboutsummaryrefslogtreecommitdiffstats
path: root/tests/handover_cfg.vty
diff options
context:
space:
mode:
Diffstat (limited to 'tests/handover_cfg.vty')
-rw-r--r--tests/handover_cfg.vty60
1 files changed, 30 insertions, 30 deletions
diff --git a/tests/handover_cfg.vty b/tests/handover_cfg.vty
index 94c20d962..8fdaf1f08 100644
--- a/tests/handover_cfg.vty
+++ b/tests/handover_cfg.vty
@@ -145,7 +145,7 @@ network
OsmoBSC(config-net-bts)# ### Verify that 'min rxlev' value range stops at -50
OsmoBSC(config-net-bts)# handover2 min rxlev ?
- <-110--50> minimum RxLev (dBm)
+ <-110--50> minimum RxLev (dBm; note: negative values)
default Use default (-100), remove explicit setting on this node
OsmoBSC(config-net-bts)# handover2 min rxlev -111
% Unknown command.
@@ -218,14 +218,14 @@ OsmoBSC(config-net)# handover2 ?
window Measurement averaging settings
power Neighbor cell power triggering
maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO
- assignment Enable or disable in-call channel re-assignment
+ assignment Enable or disable in-call channel re-assignment within the same cell
tdma-measurement Define measurement set of TDMA frames
min Minimum Level/Quality thresholds before triggering HO
afs-bias Configure bias to prefer AFS (AMR on TCH/F) over other codecs
min-free-slots Minimum free TCH timeslots before cell is considered congested
max-handovers Maximum number of concurrent handovers allowed per cell
penalty-time Set penalty times to wait between repeated handovers
- retries Immediately retry on handover/assignment failure
+ retries Number of times to immediately retry a failed handover/assignment, before a penalty time is applied
congestion-check Configure congestion check interval
OsmoBSC(config-net)# handover algorithm ?
@@ -238,22 +238,22 @@ OsmoBSC(config-net)# handover1 window ?
rxqual Received-Quality averaging
OsmoBSC(config-net)# handover1 window rxlev ?
- averaging How many RxLev measurements are used for averaging
- neighbor How many Neighbor RxLev measurements are used for averaging
+ averaging How many RxLev measurements to use for averaging
+ neighbor How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net)# handover1 window rxlev averaging ?
<1-10> RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net)# handover1 window rxlev neighbor ?
- averaging How many Neighbor RxLev measurements are used for averaging
+ averaging How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net)# handover1 window rxlev neighbor averaging ?
<1-10> Neighbor RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net)# handover1 window rxqual ?
- averaging How many RxQual measurements are used for averaging
+ averaging How many RxQual measurements to use for averaging
OsmoBSC(config-net)# handover1 window rxqual averaging ?
<1-10> RxQual averaging: Number of values to average over
@@ -286,22 +286,22 @@ OsmoBSC(config-net)# handover2 window ?
rxqual Received-Quality averaging
OsmoBSC(config-net)# handover2 window rxlev ?
- averaging How many RxLev measurements are used for averaging
- neighbor How many Neighbor RxLev measurements are used for averaging
+ averaging How many RxLev measurements to use for averaging
+ neighbor How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net)# handover2 window rxlev averaging ?
<1-10> RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net)# handover2 window rxlev neighbor ?
- averaging How many Neighbor RxLev measurements are used for averaging
+ averaging How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net)# handover2 window rxlev neighbor averaging ?
<1-10> Neighbor RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net)# handover2 window rxqual ?
- averaging How many RxQual measurements are used for averaging
+ averaging How many RxQual measurements to use for averaging
OsmoBSC(config-net)# handover2 window rxqual averaging ?
<1-10> RxQual averaging: Number of values to average over
@@ -344,7 +344,7 @@ OsmoBSC(config-net)# handover2 min ?
rxqual How bad may RxQual of an MS become before triggering HO
OsmoBSC(config-net)# handover2 min rxlev ?
- <-110--50> minimum RxLev (dBm)
+ <-110--50> minimum RxLev (dBm; note: negative values)
default Use default (-100), remove explicit setting on this node
OsmoBSC(config-net)# handover2 min rxqual ?
@@ -383,9 +383,9 @@ OsmoBSC(config-net)# handover2 max-handovers ?
default Use default (9999), remove explicit setting on this node
OsmoBSC(config-net)# handover2 penalty-time ?
- max-distance Time to suspend handovers after leaving this cell due to exceeding max distance
- failed-ho Time to suspend handovers after handover failure to this cell
- failed-assignment Time to suspend handovers after assignment failure in this cell
+ max-distance Time to suspend handover for a subscriber after leaving this cell due to exceeding max distance; see also 'handover2 retries'
+ failed-ho Time to suspend handover for a subscriber after a failed handover into this cell; see also 'handover2 retries'
+ failed-assignment Time to suspend handover for a subscriber after a failed re-assignment within this cell; see also 'handover2 retries'
OsmoBSC(config-net)# handover2 penalty-time max-distance ?
<0-99999> Seconds
@@ -404,7 +404,7 @@ OsmoBSC(config-net)# handover2 retries ?
default Use default (0), remove explicit setting on this node
OsmoBSC(config-net)# handover2 congestion-check ?
- disabled Disable congestion checking, do not handover based on cell overload
+ disabled Disable congestion checking, do not handover based on cell load. Note: there is one global congestion check interval, i.e. contrary to other handover2 settings, this is not configurable per individual cell.
<1-999> Congestion check interval in seconds (default 10)
now Manually trigger a congestion check to run right now
@@ -437,14 +437,14 @@ OsmoBSC(config-net-bts)# handover2 ?
window Measurement averaging settings
power Neighbor cell power triggering
maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO
- assignment Enable or disable in-call channel re-assignment
+ assignment Enable or disable in-call channel re-assignment within the same cell
tdma-measurement Define measurement set of TDMA frames
min Minimum Level/Quality thresholds before triggering HO
afs-bias Configure bias to prefer AFS (AMR on TCH/F) over other codecs
min-free-slots Minimum free TCH timeslots before cell is considered congested
max-handovers Maximum number of concurrent handovers allowed per cell
penalty-time Set penalty times to wait between repeated handovers
- retries Immediately retry on handover/assignment failure
+ retries Number of times to immediately retry a failed handover/assignment, before a penalty time is applied
OsmoBSC(config-net-bts)# handover algorithm ?
1 Algorithm 1: trigger handover based on comparing current cell and neighbor RxLev and RxQual, only.
@@ -456,22 +456,22 @@ OsmoBSC(config-net-bts)# handover1 window ?
rxqual Received-Quality averaging
OsmoBSC(config-net-bts)# handover1 window rxlev ?
- averaging How many RxLev measurements are used for averaging
- neighbor How many Neighbor RxLev measurements are used for averaging
+ averaging How many RxLev measurements to use for averaging
+ neighbor How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net-bts)# handover1 window rxlev averaging ?
<1-10> RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net-bts)# handover1 window rxlev neighbor ?
- averaging How many Neighbor RxLev measurements are used for averaging
+ averaging How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net-bts)# handover1 window rxlev neighbor averaging ?
<1-10> Neighbor RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net-bts)# handover1 window rxqual ?
- averaging How many RxQual measurements are used for averaging
+ averaging How many RxQual measurements to use for averaging
OsmoBSC(config-net-bts)# handover1 window rxqual averaging ?
<1-10> RxQual averaging: Number of values to average over
@@ -504,22 +504,22 @@ OsmoBSC(config-net-bts)# handover2 window ?
rxqual Received-Quality averaging
OsmoBSC(config-net-bts)# handover2 window rxlev ?
- averaging How many RxLev measurements are used for averaging
- neighbor How many Neighbor RxLev measurements are used for averaging
+ averaging How many RxLev measurements to use for averaging
+ neighbor How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net-bts)# handover2 window rxlev averaging ?
<1-10> RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net-bts)# handover2 window rxlev neighbor ?
- averaging How many Neighbor RxLev measurements are used for averaging
+ averaging How many Neighbor RxLev measurements to use for averaging
OsmoBSC(config-net-bts)# handover2 window rxlev neighbor averaging ?
<1-10> Neighbor RxLev averaging: Number of values to average over
default Use default (10), remove explicit setting on this node
OsmoBSC(config-net-bts)# handover2 window rxqual ?
- averaging How many RxQual measurements are used for averaging
+ averaging How many RxQual measurements to use for averaging
OsmoBSC(config-net-bts)# handover2 window rxqual averaging ?
<1-10> RxQual averaging: Number of values to average over
@@ -562,7 +562,7 @@ OsmoBSC(config-net-bts)# handover2 min ?
rxqual How bad may RxQual of an MS become before triggering HO
OsmoBSC(config-net-bts)# handover2 min rxlev ?
- <-110--50> minimum RxLev (dBm)
+ <-110--50> minimum RxLev (dBm; note: negative values)
default Use default (-100), remove explicit setting on this node
OsmoBSC(config-net-bts)# handover2 min rxqual ?
@@ -601,9 +601,9 @@ OsmoBSC(config-net-bts)# handover2 max-handovers ?
default Use default (9999), remove explicit setting on this node
OsmoBSC(config-net-bts)# handover2 penalty-time ?
- max-distance Time to suspend handovers after leaving this cell due to exceeding max distance
- failed-ho Time to suspend handovers after handover failure to this cell
- failed-assignment Time to suspend handovers after assignment failure in this cell
+ max-distance Time to suspend handover for a subscriber after leaving this cell due to exceeding max distance; see also 'handover2 retries'
+ failed-ho Time to suspend handover for a subscriber after a failed handover into this cell; see also 'handover2 retries'
+ failed-assignment Time to suspend handover for a subscriber after a failed re-assignment within this cell; see also 'handover2 retries'
OsmoBSC(config-net-bts)# handover2 penalty-time max-distance ?
<0-99999> Seconds