diff options
author | Neels Hofmeyr <neels@hofmeyr.de> | 2021-07-05 17:38:28 +0200 |
---|---|---|
committer | laforge <laforge@osmocom.org> | 2021-07-09 11:51:40 +0000 |
commit | 9d4865ecaea5dc17e3058777620d52e8efa4c8a5 (patch) | |
tree | 116172ceed098ba7c2f8f652862606640bc2a70e /tests | |
parent | 7225fe49026bcc8e312ef6e5a2f40f4e385529cf (diff) |
hodec2: [2/2] implement automatic choice between FULL and SUBSET measurements
Add TDMA_MEAS_SET_AUTO to indicate automatic choice between FULL and
SUBSET measurements depending on DTX. So far use only in hodec2.
TDMA_MEAS_SET_AUTO looks at each individual measurement report's DTX
flag and for each report chooses FULL if DTX is not used, or SUB if DTX
is used.
The default setting for 'handover2 tdma-measurement' is still 'subset'.
To use the automatic choice, users need configure
handover2 tdma-measurement auto
Change-Id: I67dce55ccf892c8679272ee5dfedc25620f0f725
Diffstat (limited to 'tests')
-rw-r--r-- | tests/bsc/Makefile.am | 1 | ||||
-rw-r--r-- | tests/handover_cfg.vty | 4 |
2 files changed, 4 insertions, 1 deletions
diff --git a/tests/bsc/Makefile.am b/tests/bsc/Makefile.am index a0bbb81b2..2f6677878 100644 --- a/tests/bsc/Makefile.am +++ b/tests/bsc/Makefile.am @@ -46,6 +46,7 @@ bsc_test_LDADD = \ $(top_builddir)/src/osmo-bsc/gsm_data.o \ $(top_builddir)/src/osmo-bsc/handover_cfg.o \ $(top_builddir)/src/osmo-bsc/handover_logic.o \ + $(top_builddir)/src/osmo-bsc/meas_rep.o \ $(top_builddir)/src/osmo-bsc/neighbor_ident.o \ $(top_builddir)/src/osmo-bsc/net_init.o \ $(top_builddir)/src/osmo-bsc/nm_common_fsm.o \ diff --git a/tests/handover_cfg.vty b/tests/handover_cfg.vty index 4bafd7225..ccb1a6b04 100644 --- a/tests/handover_cfg.vty +++ b/tests/handover_cfg.vty @@ -178,7 +178,7 @@ OsmoBSC(config-net)# list handover2 power budget hysteresis (<0-999>|default) handover2 maximum distance (<0-9999>|default) handover2 assignment (0|1|default) - handover2 tdma-measurement (full|subset|default) + handover2 tdma-measurement (auto|full|subset|default) handover2 min rxlev (<-110--50>|default) handover2 min rxqual (<0-7>|default) handover2 afs-bias rxlev (<0-20>|default) @@ -335,6 +335,7 @@ OsmoBSC(config-net)# handover2 assignment ? default Use default (0), remove explicit setting on this node OsmoBSC(config-net)# handover2 tdma-measurement ? + auto Use full set when DTX is not in use, use subset when DTX is in use, as indicated by each Measurement Report full Full set of 102/104 TDMA frames subset Sub set of 4 TDMA frames (SACCH) default Use default (subset), remove explicit setting on this node @@ -553,6 +554,7 @@ OsmoBSC(config-net-bts)# handover2 assignment ? default Use default (0), remove explicit setting on this node OsmoBSC(config-net-bts)# handover2 tdma-measurement ? + auto Use full set when DTX is not in use, use subset when DTX is in use, as indicated by each Measurement Report full Full set of 102/104 TDMA frames subset Sub set of 4 TDMA frames (SACCH) default Use default (subset), remove explicit setting on this node |