diff options
author | Neels Hofmeyr <neels@hofmeyr.de> | 2019-06-24 13:43:06 +0200 |
---|---|---|
committer | neels <nhofmeyr@sysmocom.de> | 2019-07-09 15:42:38 +0000 |
commit | 08371ecc01a996f552ecfd4be9b3b738a9809e05 (patch) | |
tree | 618aeb2345448d2c165d50cdb0e8fb7401583f85 /tests | |
parent | 0fb9206c6a4032233a505267cc67d0e4f915a584 (diff) |
doc/manuals, vty doc: more handover doc clarifications
Related: OS#3487
Change-Id: I1639efb2dbcca4f0e9c33a74f3067606ce5f4209
Diffstat (limited to 'tests')
-rw-r--r-- | tests/handover_cfg.vty | 60 |
1 files changed, 30 insertions, 30 deletions
diff --git a/tests/handover_cfg.vty b/tests/handover_cfg.vty index 94c20d962..8fdaf1f08 100644 --- a/tests/handover_cfg.vty +++ b/tests/handover_cfg.vty @@ -145,7 +145,7 @@ network OsmoBSC(config-net-bts)# ### Verify that 'min rxlev' value range stops at -50 OsmoBSC(config-net-bts)# handover2 min rxlev ? - <-110--50> minimum RxLev (dBm) + <-110--50> minimum RxLev (dBm; note: negative values) default Use default (-100), remove explicit setting on this node OsmoBSC(config-net-bts)# handover2 min rxlev -111 % Unknown command. @@ -218,14 +218,14 @@ OsmoBSC(config-net)# handover2 ? window Measurement averaging settings power Neighbor cell power triggering maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO - assignment Enable or disable in-call channel re-assignment + assignment Enable or disable in-call channel re-assignment within the same cell tdma-measurement Define measurement set of TDMA frames min Minimum Level/Quality thresholds before triggering HO afs-bias Configure bias to prefer AFS (AMR on TCH/F) over other codecs min-free-slots Minimum free TCH timeslots before cell is considered congested max-handovers Maximum number of concurrent handovers allowed per cell penalty-time Set penalty times to wait between repeated handovers - retries Immediately retry on handover/assignment failure + retries Number of times to immediately retry a failed handover/assignment, before a penalty time is applied congestion-check Configure congestion check interval OsmoBSC(config-net)# handover algorithm ? @@ -238,22 +238,22 @@ OsmoBSC(config-net)# handover1 window ? rxqual Received-Quality averaging OsmoBSC(config-net)# handover1 window rxlev ? - averaging How many RxLev measurements are used for averaging - neighbor How many Neighbor RxLev measurements are used for averaging + averaging How many RxLev measurements to use for averaging + neighbor How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net)# handover1 window rxlev averaging ? <1-10> RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net)# handover1 window rxlev neighbor ? - averaging How many Neighbor RxLev measurements are used for averaging + averaging How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net)# handover1 window rxlev neighbor averaging ? <1-10> Neighbor RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net)# handover1 window rxqual ? - averaging How many RxQual measurements are used for averaging + averaging How many RxQual measurements to use for averaging OsmoBSC(config-net)# handover1 window rxqual averaging ? <1-10> RxQual averaging: Number of values to average over @@ -286,22 +286,22 @@ OsmoBSC(config-net)# handover2 window ? rxqual Received-Quality averaging OsmoBSC(config-net)# handover2 window rxlev ? - averaging How many RxLev measurements are used for averaging - neighbor How many Neighbor RxLev measurements are used for averaging + averaging How many RxLev measurements to use for averaging + neighbor How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net)# handover2 window rxlev averaging ? <1-10> RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net)# handover2 window rxlev neighbor ? - averaging How many Neighbor RxLev measurements are used for averaging + averaging How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net)# handover2 window rxlev neighbor averaging ? <1-10> Neighbor RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net)# handover2 window rxqual ? - averaging How many RxQual measurements are used for averaging + averaging How many RxQual measurements to use for averaging OsmoBSC(config-net)# handover2 window rxqual averaging ? <1-10> RxQual averaging: Number of values to average over @@ -344,7 +344,7 @@ OsmoBSC(config-net)# handover2 min ? rxqual How bad may RxQual of an MS become before triggering HO OsmoBSC(config-net)# handover2 min rxlev ? - <-110--50> minimum RxLev (dBm) + <-110--50> minimum RxLev (dBm; note: negative values) default Use default (-100), remove explicit setting on this node OsmoBSC(config-net)# handover2 min rxqual ? @@ -383,9 +383,9 @@ OsmoBSC(config-net)# handover2 max-handovers ? default Use default (9999), remove explicit setting on this node OsmoBSC(config-net)# handover2 penalty-time ? - max-distance Time to suspend handovers after leaving this cell due to exceeding max distance - failed-ho Time to suspend handovers after handover failure to this cell - failed-assignment Time to suspend handovers after assignment failure in this cell + max-distance Time to suspend handover for a subscriber after leaving this cell due to exceeding max distance; see also 'handover2 retries' + failed-ho Time to suspend handover for a subscriber after a failed handover into this cell; see also 'handover2 retries' + failed-assignment Time to suspend handover for a subscriber after a failed re-assignment within this cell; see also 'handover2 retries' OsmoBSC(config-net)# handover2 penalty-time max-distance ? <0-99999> Seconds @@ -404,7 +404,7 @@ OsmoBSC(config-net)# handover2 retries ? default Use default (0), remove explicit setting on this node OsmoBSC(config-net)# handover2 congestion-check ? - disabled Disable congestion checking, do not handover based on cell overload + disabled Disable congestion checking, do not handover based on cell load. Note: there is one global congestion check interval, i.e. contrary to other handover2 settings, this is not configurable per individual cell. <1-999> Congestion check interval in seconds (default 10) now Manually trigger a congestion check to run right now @@ -437,14 +437,14 @@ OsmoBSC(config-net-bts)# handover2 ? window Measurement averaging settings power Neighbor cell power triggering maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO - assignment Enable or disable in-call channel re-assignment + assignment Enable or disable in-call channel re-assignment within the same cell tdma-measurement Define measurement set of TDMA frames min Minimum Level/Quality thresholds before triggering HO afs-bias Configure bias to prefer AFS (AMR on TCH/F) over other codecs min-free-slots Minimum free TCH timeslots before cell is considered congested max-handovers Maximum number of concurrent handovers allowed per cell penalty-time Set penalty times to wait between repeated handovers - retries Immediately retry on handover/assignment failure + retries Number of times to immediately retry a failed handover/assignment, before a penalty time is applied OsmoBSC(config-net-bts)# handover algorithm ? 1 Algorithm 1: trigger handover based on comparing current cell and neighbor RxLev and RxQual, only. @@ -456,22 +456,22 @@ OsmoBSC(config-net-bts)# handover1 window ? rxqual Received-Quality averaging OsmoBSC(config-net-bts)# handover1 window rxlev ? - averaging How many RxLev measurements are used for averaging - neighbor How many Neighbor RxLev measurements are used for averaging + averaging How many RxLev measurements to use for averaging + neighbor How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net-bts)# handover1 window rxlev averaging ? <1-10> RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net-bts)# handover1 window rxlev neighbor ? - averaging How many Neighbor RxLev measurements are used for averaging + averaging How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net-bts)# handover1 window rxlev neighbor averaging ? <1-10> Neighbor RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net-bts)# handover1 window rxqual ? - averaging How many RxQual measurements are used for averaging + averaging How many RxQual measurements to use for averaging OsmoBSC(config-net-bts)# handover1 window rxqual averaging ? <1-10> RxQual averaging: Number of values to average over @@ -504,22 +504,22 @@ OsmoBSC(config-net-bts)# handover2 window ? rxqual Received-Quality averaging OsmoBSC(config-net-bts)# handover2 window rxlev ? - averaging How many RxLev measurements are used for averaging - neighbor How many Neighbor RxLev measurements are used for averaging + averaging How many RxLev measurements to use for averaging + neighbor How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net-bts)# handover2 window rxlev averaging ? <1-10> RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net-bts)# handover2 window rxlev neighbor ? - averaging How many Neighbor RxLev measurements are used for averaging + averaging How many Neighbor RxLev measurements to use for averaging OsmoBSC(config-net-bts)# handover2 window rxlev neighbor averaging ? <1-10> Neighbor RxLev averaging: Number of values to average over default Use default (10), remove explicit setting on this node OsmoBSC(config-net-bts)# handover2 window rxqual ? - averaging How many RxQual measurements are used for averaging + averaging How many RxQual measurements to use for averaging OsmoBSC(config-net-bts)# handover2 window rxqual averaging ? <1-10> RxQual averaging: Number of values to average over @@ -562,7 +562,7 @@ OsmoBSC(config-net-bts)# handover2 min ? rxqual How bad may RxQual of an MS become before triggering HO OsmoBSC(config-net-bts)# handover2 min rxlev ? - <-110--50> minimum RxLev (dBm) + <-110--50> minimum RxLev (dBm; note: negative values) default Use default (-100), remove explicit setting on this node OsmoBSC(config-net-bts)# handover2 min rxqual ? @@ -601,9 +601,9 @@ OsmoBSC(config-net-bts)# handover2 max-handovers ? default Use default (9999), remove explicit setting on this node OsmoBSC(config-net-bts)# handover2 penalty-time ? - max-distance Time to suspend handovers after leaving this cell due to exceeding max distance - failed-ho Time to suspend handovers after handover failure to this cell - failed-assignment Time to suspend handovers after assignment failure in this cell + max-distance Time to suspend handover for a subscriber after leaving this cell due to exceeding max distance; see also 'handover2 retries' + failed-ho Time to suspend handover for a subscriber after a failed handover into this cell; see also 'handover2 retries' + failed-assignment Time to suspend handover for a subscriber after a failed re-assignment within this cell; see also 'handover2 retries' OsmoBSC(config-net-bts)# handover2 penalty-time max-distance ? <0-99999> Seconds |