diff options
author | Oliver Smith <osmith@sysmocom.de> | 2021-08-06 16:11:16 +0200 |
---|---|---|
committer | Oliver Smith <osmith@sysmocom.de> | 2021-08-06 16:11:16 +0200 |
commit | d8f8919a5850390dbbdd9dbea266f7f569abab7e (patch) | |
tree | 22c3c5030424571e8fa2ced68bdc93acd6c16043 | |
parent | 7af860fb78d6a13258d5887e7bb71276509229cb (diff) |
vty/ports: prepare formatting for a long define
Add one more tab between the define and the port number, to prepare for
longer defines in the next patch.
Related: OS#5203
Change-Id: I46655e33651814f41a1fea93406a83334d2fc529
-rw-r--r-- | include/osmocom/vty/ports.h | 44 |
1 files changed, 22 insertions, 22 deletions
diff --git a/include/osmocom/vty/ports.h b/include/osmocom/vty/ports.h index b3550d15..cca2dd35 100644 --- a/include/osmocom/vty/ports.h +++ b/include/osmocom/vty/ports.h @@ -9,32 +9,32 @@ #pragma once /* 4236 used by control interface */ -#define OSMO_VTY_PORT_TRX 4237 +#define OSMO_VTY_PORT_TRX 4237 /* 4238 used by osmo-bts control interface */ -#define OSMO_VTY_PORT_STP 4239 -#define OSMO_VTY_PORT_PCU 4240 /* also: osmo_pcap_client */ -#define OSMO_VTY_PORT_BTS 4241 /* also: osmo_pcap_server */ -#define OSMO_VTY_PORT_NITB_BSC 4242 -#define OSMO_VTY_PORT_BSC_MGCP 4243 -#define OSMO_VTY_PORT_MGW OSMO_VTY_PORT_BSC_MGCP -#define OSMO_VTY_PORT_BSC_NAT 4244 -#define OSMO_VTY_PORT_SGSN 4245 -#define OSMO_VTY_PORT_GBPROXY 4246 -#define OSMO_VTY_PORT_BB 4247 +#define OSMO_VTY_PORT_STP 4239 +#define OSMO_VTY_PORT_PCU 4240 /* also: osmo_pcap_client */ +#define OSMO_VTY_PORT_BTS 4241 /* also: osmo_pcap_server */ +#define OSMO_VTY_PORT_NITB_BSC 4242 +#define OSMO_VTY_PORT_BSC_MGCP 4243 +#define OSMO_VTY_PORT_MGW OSMO_VTY_PORT_BSC_MGCP +#define OSMO_VTY_PORT_BSC_NAT 4244 +#define OSMO_VTY_PORT_SGSN 4245 +#define OSMO_VTY_PORT_GBPROXY 4246 +#define OSMO_VTY_PORT_BB 4247 /* 4249-4251 used by control interface */ -#define OSMO_VTY_PORT_BTSMGR 4252 -#define OSMO_VTY_PORT_GTPHUB 4253 -#define OSMO_VTY_PORT_MSC 4254 +#define OSMO_VTY_PORT_BTSMGR 4252 +#define OSMO_VTY_PORT_GTPHUB 4253 +#define OSMO_VTY_PORT_MSC 4254 /* 4255 used by control interface */ -#define OSMO_VTY_PORT_MNCC_SIP 4256 +#define OSMO_VTY_PORT_MNCC_SIP 4256 /* 4257 used by control interface */ -#define OSMO_VTY_PORT_HLR 4258 +#define OSMO_VTY_PORT_HLR 4258 /* 4259 used by control interface */ -#define OSMO_VTY_PORT_GGSN 4260 -#define OSMO_VTY_PORT_HNBGW 4261 +#define OSMO_VTY_PORT_GGSN 4260 +#define OSMO_VTY_PORT_HNBGW 4261 /* 4262-4263 used by control interface */ -#define OSMO_VTY_PORT_CBC 4264 -#define OSMO_VTY_PORT_UECUPS 4268 -#define OSMO_VTY_PORT_E1D 4269 -#define OSMO_VTY_PORT_SMLC 4271 +#define OSMO_VTY_PORT_CBC 4264 +#define OSMO_VTY_PORT_UECUPS 4268 +#define OSMO_VTY_PORT_E1D 4269 +#define OSMO_VTY_PORT_SMLC 4271 /* When adding/changing port numbers, keep docs and wiki in sync. See above. */ |