diff options
Diffstat (limited to '1.4.23-rc4/configs/alarmreceiver.conf.sample')
-rw-r--r-- | 1.4.23-rc4/configs/alarmreceiver.conf.sample | 80 |
1 files changed, 80 insertions, 0 deletions
diff --git a/1.4.23-rc4/configs/alarmreceiver.conf.sample b/1.4.23-rc4/configs/alarmreceiver.conf.sample new file mode 100644 index 000000000..bf767dea3 --- /dev/null +++ b/1.4.23-rc4/configs/alarmreceiver.conf.sample @@ -0,0 +1,80 @@ +; +; alarmreceiver.conf +; +; Sample configuration file for the Asterisk alarm receiver application. +; + + +[general] + +; +; Specify a timestamp format for the metadata section of the event files +; Default is %a %b %d, %Y @ %H:%M:%S %Z + +timestampformat = %a %b %d, %Y @ %H:%M:%S %Z + +; +; Specify a command to execute when the caller hangs up +; +; Default is none +; + +;eventcmd = yourprogram -yourargs ... + +; +; Specify a spool directory for the event files. This setting is required +; if you want the app to be useful. Event files written to the spool +; directory will be of the template event-XXXXXX, where XXXXXX is a random +; and unique alphanumeric string. +; +; Default is none, and the events will be dropped on the floor. +; + +eventspooldir = /tmp + +; +; The alarmreceiver app can either log the events one-at-a-time to individual +; files in the spool directory, or it can store them until the caller +; disconnects and write them all to one file. +; +; The default setting for logindividualevents is no. +; + +logindividualevents = no + +; +; The timeout for receiving the first DTMF digit is adjustable from 1000 msec. +; to 10000 msec. The default is 2000 msec. Note: if you wish to test the +; receiver by entering digits manually, set this to a reasonable time out +; like 10000 milliseconds. + +fdtimeout = 2000 + +; +; The timeout for receiving subsequent DTMF digits is adjustable from +; 110 msec. to 4000 msec. The default is 200 msec. Note: if you wish to test +; the receiver by entering digits manually, set this to a reasonable time out +; like 4000 milliseconds. +; + +sdtimeout = 200 + +; +; The loudness of the ACK and Kissoff tones is adjustable from 100 to 8192. +; The default is 8192. This shouldn't need to be messed with, but is included +; just in case there are problems with signal levels. +; + +loudness = 8192 + +; +; The db-family setting allows the user to capture statistics on the number of +; calls, and the errors the alarm receiver sees. The default is for no +; db-family name to be defined and the database logging to be turned off. +; + +;db-family = yourfamily: + +; +; End of alarmreceiver.conf +; |