diff options
author | Kévin Redon <kredon@sysmocom.de> | 2019-09-03 21:13:42 +0200 |
---|---|---|
committer | Kévin Redon <kredon@sysmocom.de> | 2019-09-03 21:13:44 +0200 |
commit | bea9406bb11943a7387eeec1b3fc3dadbd396def (patch) | |
tree | be2506dda642c402d3e0279bb81ab0f0676d915a /hardware/datasheet/LDO_AP7332.pdf | |
parent | 614ce7a7d83798109d90f6997696212387900526 (diff) |
schematic: mark USB reset circuit as dot no place
the additional circuit to reset USB (by pulling D+ low) is not
required anymore since the USB controller in the SAM3S integrates
this capability.
the SAM3S-EK Development Board also demonstrates only the inline
27 Ohm termination resistors are required.
this change has been tested (behind 2 USB HUBs).
the RESET button still works.
resetting using DFU into the bootloader and starting the
application from the bootloader still works.
Change-Id: I648a041f6d3cf456f1783249546078961f85e662
Diffstat (limited to 'hardware/datasheet/LDO_AP7332.pdf')
0 files changed, 0 insertions, 0 deletions