@@ -59,7 +59,7 @@ reached, a higher coding scheme is chosen.
You can use the `cs link-quality-ranges cs1 <0-35> cs2 <0-35> <0-35> cs3
<0-35> <0-35> cs4 <0-35>` command at the `pcu` VTY config node to tune
-the link quality ranges for the respecive coding schemes.
+the link quality ranges for the respective coding schemes.
==== Data Size based CS downgrade Threshold
@@ -114,7 +114,7 @@ filter).
==== Normal BSSGP Flow Control Tuning parameters
You can use the following commands at the `pcu` VTY config node to tune
-the the BSSGP flow control parameters:
+the BSSGP flow control parameters:
`flow-control-interval <1-10>`::
configure the interval (in seconds) between subsequent flow
@@ -185,7 +185,7 @@ parameters.
You can set those parameters at the `pcu` VTY config node as follows:
`alpha <0-10>`::
- Alpha parameter for MS power contrl in units of 0.1.
+ Alpha parameter for MS power control in units of 0.1.
Make sure to set the alpha value at System Information 13 (in
the BSC), too!