authoraravind sirsikar <arvind.sirsikar@radisys.com>2016-11-11 17:15:10 +0530
committeraravind sirsikar <arvind.sirsikar@radisys.com>2016-11-11 17:15:10 +0530
commited3413e39740c78148719696b0903874add580e2 (patch)
treea448e909658802c00f6d99d89d9a51cfb18a80c5 /tests/tbf/TbfTest.err
parentc0c3afd0794c217e6fc33b18eb9366c8cfe8b020 (diff)
Handle packet access reject during EPDAN/PDAN with channel description
When PDAN/EPDAN with channel description is received, PCU will generate the packet access reject if no resources are present. The encoding is done based on section 7.1.3.2.1 and 8.1.2.5 of 44.060 version 7.27.0 Release 7. This patch also includes the test case to validate the generated packet access reject message. This patch is integration tested on Osmo-trx setup with Ettus B210 board and LG F70 MS with some simulation code changes in Osmo-pcu. Change-Id: I096a3bb44a65533b9e9b091925dd5f70a8696d6
Diffstat (limited to 'tests/tbf/TbfTest.err')
-rw-r--r--tests/tbf/TbfTest.err24
1 files changed, 24 insertions, 0 deletions
diff --git a/tests/tbf/TbfTest.err b/tests/tbf/TbfTest.err
index 627cdc30..a6808122 100644
--- a/tests/tbf/TbfTest.err
+++ b/tests/tbf/TbfTest.err
@@ -6846,3 +6846,27 @@ MS requests single block allocation
No PDCH available.
No PDCH resource for single block allocation.sending Immediate Assignment Uplink (AGCH) reject
Sending data request: trx=0 ts=0 sapi=2 arfcn=0 fn=0 block=0 data=4d 06 3a 10 70 8b 29 14 70 8b 29 14 70 8b 29 14 70 8b 29 14 0b 2b 2b
+Searching for first unallocated TFI: TRX=0
+ Found TFI=0.
+********** TBF starts here **********
+Allocating DL TBF: MS_CLASS=11/11
+Creating MS object, TLLI = 0x00000000
+Modifying MS object, TLLI = 0x00000000, MS class 0 -> 11
+Modifying MS object, TLLI = 0x00000000, EGPRS MS class 0 -> 11
+Slot Allocation (Algorithm A) for class 11
+- Skipping TS 0, because not enabled
+- Skipping TS 1, because not enabled
+- Skipping TS 2, because not enabled
+- Skipping TS 3, because not enabled
+- Skipping TS 5, because not enabled
+- Skipping TS 6, because not enabled
+- Skipping TS 7, because not enabled
+- Assign downlink TS=4 TFI=0
+PDCH(TS 4, TRX 0): Attaching TBF(TFI=0 TLLI=0x00000000 DIR=DL STATE=NULL), 1 TBFs, USFs = 00, TFIs = 00000001.
+- Setting Control TS 4
+Attaching TBF to MS object, TLLI = 0x00000000, TBF = TBF(TFI=0 TLLI=0x00000000 DIR=DL STATE=NULL)
+Allocated TBF(TFI=0 TLLI=0x00000000 DIR=DL STATE=NULL): trx = 0, ul_slots = 10, dl_slots = 10
+Modifying MS object, TLLI = 0x00000000, TA 220 -> 0
+TBF(TFI=0 TLLI=0x00000000 DIR=DL STATE=NULL) changes state from NULL to FLOW
+The MS object cannot fully confirm an unexpected TLLI: 0xffeeddcc, partly confirmed
+TBF(TFI=0 TLLI=0xffeeddcc DIR=DL STATE=FLOW) append