From d7be09caf8d49ac65ed626bca9de2fb738a365b6 Mon Sep 17 00:00:00 2001 From: Harald Welte Date: Wed, 22 May 2019 22:35:45 +0200 Subject: sysmo: Fix "nominal power" / BS power display in VTY The function get_p_max_out_mdBm() returns a value in 1/1000th of dBm, "milli-dBm", while trx->nominal_power is only whole dBm. We were missing the required divider of 1000 ever since Change-Id Ieff75d5becaa80a2097b6e744c75c2d16259c9a4 was merged in February 2017. The good news is that this really only affected the VTY output and not any actual operational aspect of the system. Change-Id: If92d0b15c48dafc63776b82c7ff5f3c2b3505f68 Closes: SYS#4570 --- src/osmo-bts-sysmo/l1_if.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) (limited to 'src/osmo-bts-sysmo/l1_if.c') diff --git a/src/osmo-bts-sysmo/l1_if.c b/src/osmo-bts-sysmo/l1_if.c index 87cf25a0..6f61c67b 100644 --- a/src/osmo-bts-sysmo/l1_if.c +++ b/src/osmo-bts-sysmo/l1_if.c @@ -1883,7 +1883,7 @@ int bts_model_phy_link_open(struct phy_link *plink) LOGP(DL1C, LOGL_NOTICE, "Cannot determine nominal " "transmit power. Assuming 23dBm.\n"); } - bts->c0->nominal_power = rc; + bts->c0->nominal_power = rc / 1000; } hdl = pinst->u.sysmobts.hdl; -- cgit v1.2.3