sysmobts: Begin to add various limits and actions
The idea is that for different parts of the system we can define thresholds for warning and critical (severe) temperate thresholds. And once any of these temperatures is reached we will execute an action. When crossing from NORMAL to WARNING or WARNING to SEVERE we will need to apply some hysteris before switching back to the lower level. E.g. when being SEVERE mode, at least wait until we are below the warning level again. Besides being able to switch off things we could start reducing the transmit power of the system until the system is cold enough again. No action is implemented so far, everything is varpoware!
Diffstat (limited to 'src/osmo-bts-sysmo')
-rw-r--r--src/osmo-bts-sysmo/misc/sysmobts_mgr.c29
-rw-r--r--src/osmo-bts-sysmo/misc/sysmobts_mgr.h50
-rw-r--r--src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c209
3 files changed, 275 insertions, 13 deletions
diff --git a/src/osmo-bts-sysmo/misc/sysmobts_mgr.c b/src/osmo-bts-sysmo/misc/sysmobts_mgr.c
index 5465816e..cc566498 100644
--- a/src/osmo-bts-sysmo/misc/sysmobts_mgr.c
+++ b/src/osmo-bts-sysmo/misc/sysmobts_mgr.c
@@ -49,9 +49,32 @@ static int trx_number;
static int no_eeprom_write = 0;
static int daemonize = 0;
-static const char *cfgfile = "sysmobts-mgr.cfg";
void *tall_mgr_ctx;
+/* the initial state */
+static struct sysmobts_mgr_instance manager = {
+ .config_file = "sysmobts-mgr.cfg",
+ .rf_limit = {
+ .thresh_warn = 60,
+ .thresh_crit = 78,
+ },
+ .digital_limit = {
+ .thresh_warn = 60,
+ .thresh_crit = 78,
+ },
+ .board_limit = {
+ .thresh_warn = 60,
+ .thresh_crit = 78,
+ },
+ .pa_limit = {
+ .thresh_warn = 60,
+ .thresh_crit = 100,
+ },
+ .action_warn = 0,
+ .action_crit = 0,
+ .state = STATE_NORMAL,
+};
+
static int classify_bts(void)
{
@@ -149,7 +172,7 @@ static int parse_options(int argc, char **argv)
daemonize = 1;
break;
case 'c':
- cfgfile = optarg;
+ manager.config_file = optarg;
break;
default:
return -1;
@@ -247,7 +270,7 @@ int main(int argc, char **argv)
sysmobts_mgr_vty_init();
logging_vty_add_cmds(&mgr_log_info);
- rc = sysmobts_mgr_parse_config(cfgfile);
+ rc = sysmobts_mgr_parse_config(&manager);
if (rc < 0) {
LOGP(DFIND, LOGL_FATAL, "Cannot parse config file\n");
exit(1);
diff --git a/src/osmo-bts-sysmo/misc/sysmobts_mgr.h b/src/osmo-bts-sysmo/misc/sysmobts_mgr.h
index c71a5493..deddaadb 100644
--- a/src/osmo-bts-sysmo/misc/sysmobts_mgr.h
+++ b/src/osmo-bts-sysmo/misc/sysmobts_mgr.h
@@ -10,15 +10,59 @@ enum {
DFIND,
};
+
+enum {
+ TEMP_ACT_PWR_CONTRL = 0x1,
+ TEMP_ACT_MASTER_OFF = 0x2,
+ TEMP_ACT_SLAVE_OFF = 0x4,
+ TEMP_ACT_PA_OFF = 0x8,
+};
+
+enum {
+ STATE_NORMAL, /* Everything is fine */
+ STATE_WARNING, /* We are above the warning threshold */
+ STATE_CRITICAL, /* We have an issue. Wait for below warning */
+};
+
+/**
+ * Temperature Limits. We separate from a threshold
+ * that will generate a warning and one that is so
+ * severe that an action will be taken.
+ */
+struct sysmobts_temp_limit {
+ int thresh_warn;
+ int thresh_crit;
+};
+
enum mgr_vty_node {
MGR_NODE = _LAST_OSMOVTY_NODE + 1,
-};
-int sysmobts_mgr_vty_init(void);
-int sysmobts_mgr_parse_config(const char *config_file);
+ ACT_WARN_NODE,
+ ACT_CRIT_NODE,
+ LIMIT_RF_NODE,
+ LIMIT_DIGITAL_NODE,
+ LIMIT_BOARD_NODE,
+ LIMIT_PA_NODE,
+};
struct sysmobts_mgr_instance {
const char *config_file;
+
+ struct sysmobts_temp_limit rf_limit;
+ struct sysmobts_temp_limit digital_limit;
+
+ /* Only available on sysmobts 2050 */
+ struct sysmobts_temp_limit board_limit;
+ struct sysmobts_temp_limit pa_limit;
+
+ int action_warn;
+ int action_crit;
+
+ int state;
};
+
+int sysmobts_mgr_vty_init(void);
+int sysmobts_mgr_parse_config(struct sysmobts_mgr_instance *mgr);
int sysmobts_mgr_nl_init(void);
+
#endif
diff --git a/src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c b/src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c
index 1cabe44a..42160708 100644
--- a/src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c
+++ b/src/osmo-bts-sysmo/misc/sysmobts_mgr_vty.c
@@ -39,6 +39,8 @@
#include "sysmobts_mgr.h"
#include "btsconfig.h"
+static struct sysmobts_mgr_instance *s_mgr;
+
static const char copyright[] =
"(C) 2012 by Harald Welte <laforge@gnumonks.org>\r\n"
"(C) 2014 by Holger Hans Peter Freyther\r\n"
@@ -52,6 +54,14 @@ static enum node_type go_to_parent(struct vty *vty)
case MGR_NODE:
vty->node = CONFIG_NODE;
break;
+ case ACT_WARN_NODE:
+ case ACT_CRIT_NODE:
+ case LIMIT_RF_NODE:
+ case LIMIT_DIGITAL_NODE:
+ case LIMIT_BOARD_NODE:
+ case LIMIT_PA_NODE:
+ vty->node = MGR_NODE;
+ break;
default:
vty->node = CONFIG_NODE;
}
@@ -62,6 +72,12 @@ static int is_config_node(struct vty *vty, int node)
{
switch (node) {
case MGR_NODE:
+ case ACT_WARN_NODE:
+ case ACT_CRIT_NODE:
+ case LIMIT_RF_NODE:
+ case LIMIT_DIGITAL_NODE:
+ case LIMIT_BOARD_NODE:
+ case LIMIT_PA_NODE:
return 1;
default:
return 0;
@@ -85,6 +101,42 @@ static struct cmd_node mgr_node = {
1,
};
+static struct cmd_node act_warn_node = {
+ ACT_WARN_NODE,
+ "%s(action-warn)# ",
+ 1,
+};
+
+static struct cmd_node act_crit_node = {
+ ACT_CRIT_NODE,
+ "%s(action-critical)# ",
+ 1,
+};
+
+static struct cmd_node limit_rf_node = {
+ LIMIT_RF_NODE,
+ "%s(limit-rf)# ",
+ 1,
+};
+
+static struct cmd_node limit_digital_node = {
+ LIMIT_DIGITAL_NODE,
+ "%s(limit-digital)# ",
+ 1,
+};
+
+static struct cmd_node limit_board_node = {
+ LIMIT_BOARD_NODE,
+ "%s(limit-board)# ",
+ 1,
+};
+
+static struct cmd_node limit_pa_node = {
+ LIMIT_PA_NODE,
+ "%s(limit-pa)# ",
+ 1,
+};
+
DEFUN(cfg_mgr, cfg_mgr_cmd,
"sysmobts-mgr",
MGR_STR)
@@ -93,6 +145,100 @@ DEFUN(cfg_mgr, cfg_mgr_cmd,
return CMD_SUCCESS;
}
+static void write_temp_limit(struct vty *vty, const char *name,
+ struct sysmobts_temp_limit *limit)
+{
+ vty_out(vty, " %s%s", name, VTY_NEWLINE);
+ vty_out(vty, " threshold warning %d%s",
+ limit->thresh_warn, VTY_NEWLINE);
+ vty_out(vty, " threshold critical %d%s",
+ limit->thresh_crit, VTY_NEWLINE);
+}
+
+static void write_action(struct vty *vty, const char *name, int actions)
+{
+ vty_out(vty, " %s%s", name, VTY_NEWLINE);
+#if 0
+ vty_out(vty, " %spower-control%s",
+ (actions & TEMP_ACT_PWR_CONTRL) ? "" : "no ", VTY_NEWLINE);
+
+ /* only on the sysmobts 2050 */
+ vty_out(vty, " %smaster-off%s",
+ (actions & TEMP_ACT_MASTER_OFF) ? "" : "no ", VTY_NEWLINE);
+ vty_out(vty, " %sslave-off%s",
+ (actions & TEMP_ACT_MASTER_OFF) ? "" : "no ", VTY_NEWLINE);
+ vty_out(vty, " %spa-off%s",
+ (actions & TEMP_ACT_PA_OFF) ? "" : "no ", VTY_NEWLINE);
+#endif
+}
+
+static int config_write_mgr(struct vty *vty)
+{
+ vty_out(vty, "sysmobts-mgr%s", VTY_NEWLINE);
+
+ write_temp_limit(vty, "limits rf", &s_mgr->rf_limit);
+ write_temp_limit(vty, "limits digital", &s_mgr->digital_limit);
+ write_temp_limit(vty, "limits board", &s_mgr->board_limit);
+ write_temp_limit(vty, "limits pa", &s_mgr->pa_limit);
+
+ write_action(vty, "actions warn", s_mgr->action_warn);
+ write_action(vty, "actions critical", s_mgr->action_crit);
+
+ return CMD_SUCCESS;
+}
+
+static int config_write_dummy(struct vty *vty)
+{
+ return CMD_SUCCESS;
+}
+
+#define CFG_LIMIT(name, expl, switch_to, variable) \
+DEFUN(cfg_limit_##name, cfg_limit_##name##_cmd, \
+ "limits " #name, \
+ "Configure Limits\n" expl) \
+{ \
+ vty->node = switch_to; \
+ vty->index = &s_mgr->variable; \
+ return CMD_SUCCESS; \
+}
+
+CFG_LIMIT(rf, "RF\n", LIMIT_RF_NODE, rf_limit)
+CFG_LIMIT(digital, "Digital\n", LIMIT_DIGITAL_NODE, digital_limit)
+CFG_LIMIT(board, "Board\n", LIMIT_BOARD_NODE, board_limit)
+CFG_LIMIT(pa, "Power Amplifier\n", LIMIT_PA_NODE, pa_limit)
+#undef CFG_LIMIT
+
+DEFUN(cfg_limit_warning, cfg_thresh_warning_cmd,
+ "threshold warning <0-200>",
+ "Threshold to reach\n" "Warning level\n" "Range\n")
+{
+ struct sysmobts_temp_limit *limit = vty->index;
+ limit->thresh_warn = atoi(argv[0]);
+ return CMD_SUCCESS;
+}
+
+DEFUN(cfg_limit_crit, cfg_thresh_crit_cmd,
+ "threshold critical <0-200>",
+ "Threshold to reach\n" "Severe level\n" "Range\n")
+{
+ struct sysmobts_temp_limit *limit = vty->index;
+ limit->thresh_crit = atoi(argv[0]);
+ return CMD_SUCCESS;
+}
+
+#define CFG_ACTION(name, expl, switch_to, variable) \
+DEFUN(cfg_action_##name, cfg_action_##name##_cmd, \
+ "actions " #name, \
+ "Configure Actions\n" expl) \
+{ \
+ vty->node = switch_to; \
+ vty->index = &s_mgr->variable; \
+ return CMD_SUCCESS; \
+}
+CFG_ACTION(warn, "Warning Actions\n", ACT_WARN_NODE, action_warn)
+CFG_ACTION(critical, "Critical Actions\n", ACT_CRIT_NODE, action_crit)
+#undef CFG_ACTION
+
DEFUN(show_mgr, show_mgr_cmd, "show manager",
SHOW_STR "Display information about the manager")
{
@@ -111,7 +257,7 @@ DEFUN(show_mgr, show_mgr_cmd, "show manager",
sbts2050_uc_check_temp(&temp_pa, &temp_board);
vty_out(vty, " sysmoBTS 2050 PA: %d Celcius%s", temp_pa, VTY_NEWLINE);
- vty_out(vty, " sysmoBTS 2050 PA: %d CelciusC%s", temp_board, VTY_NEWLINE);
+ vty_out(vty, " sysmoBTS 2050 PA: %d Celcius%s", temp_board, VTY_NEWLINE);
sbts2050_uc_get_status(&status);
vty_out(vty, "Power Status%s", VTY_NEWLINE);
@@ -138,10 +284,26 @@ DEFUN(show_mgr, show_mgr_cmd, "show manager",
return CMD_SUCCESS;
}
-static int config_write_mgr(struct vty *vty)
+static void register_limit(int limit)
{
- vty_out(vty, "sysmobts-mgr%s", VTY_NEWLINE);
- return CMD_SUCCESS;
+ install_element(limit, &cfg_thresh_warning_cmd);
+ install_element(limit, &cfg_thresh_crit_cmd);
+}
+
+static void register_action(int act)
+{
+#if 0
+ install_element(act, &cfg_action_pwr_contrl_cmd);
+ install_element(act, &cfg_no_action_pwr_contrl_cmd);
+
+ /* these only work on the sysmobts 2050 */
+ install_element(act, &cfg_action_master_off_cmd);
+ install_element(act, &cfg_no_action_master_off_cmd);
+ install_element(act, &cfg_action_slave_off_cmd);
+ install_element(act, &cfg_no_action_slave_off_cmd);
+ install_element(act, &cfg_action_pa_off_cmd);
+ install_element(act, &cfg_no_action_pa_off_cmd);
+#endif
}
int sysmobts_mgr_vty_init(void)
@@ -154,17 +316,50 @@ int sysmobts_mgr_vty_init(void)
install_element(CONFIG_NODE, &cfg_mgr_cmd);
vty_install_default(MGR_NODE);
+ /* install the limit nodes */
+ install_node(&limit_rf_node, config_write_dummy);
+ install_element(MGR_NODE, &cfg_limit_rf_cmd);
+ register_limit(LIMIT_RF_NODE);
+ vty_install_default(LIMIT_RF_NODE);
+
+ install_node(&limit_digital_node, config_write_dummy);
+ install_element(MGR_NODE, &cfg_limit_digital_cmd);
+ register_limit(LIMIT_DIGITAL_NODE);
+ vty_install_default(LIMIT_DIGITAL_NODE);
+
+ install_node(&limit_board_node, config_write_dummy);
+ install_element(MGR_NODE, &cfg_limit_board_cmd);
+ register_limit(LIMIT_BOARD_NODE);
+ vty_install_default(LIMIT_BOARD_NODE);
+
+ install_node(&limit_pa_node, config_write_dummy);
+ install_element(MGR_NODE, &cfg_limit_pa_cmd);
+ register_limit(LIMIT_PA_NODE);
+ vty_install_default(LIMIT_PA_NODE);
+
+ /* install the warning and critical node */
+ install_node(&act_warn_node, config_write_dummy);
+ install_element(MGR_NODE, &cfg_action_warn_cmd);
+ register_action(ACT_WARN_NODE);
+ vty_install_default(ACT_WARN_NODE);
+
+ install_node(&act_crit_node, config_write_dummy);
+ install_element(MGR_NODE, &cfg_action_critical_cmd);
+ register_action(ACT_CRIT_NODE);
+ vty_install_default(ACT_CRIT_NODE);
+
return 0;
}
-int sysmobts_mgr_parse_config(const char *config_file)
+int sysmobts_mgr_parse_config(struct sysmobts_mgr_instance *manager)
{
int rc;
- rc = vty_read_config_file(config_file, NULL);
+ s_mgr = manager;
+ rc = vty_read_config_file(s_mgr->config_file, NULL);
if (rc < 0) {
fprintf(stderr, "Failed to parse the config file: '%s'\n",
- config_file);
+ s_mgr->config_file);
return rc;
}